scispace - formally typeset
Search or ask a question

Showing papers on "Exoskeleton Device published in 2017"


Journal ArticleDOI
01 Feb 2017
TL;DR: Current lower limb robotic exoskeletons are described, with specific regard to common trends in the field, and a number of emerging technologies could deliver substantial advantages to existing and future exoskeleton designs.
Abstract: Research on robotic exoskeletons has rapidly expanded over the previous decade. Advances in robotic hardware and energy supplies have enabled viable prototypes for human testing. This review paper describes current lower limb robotic exoskeletons, with specific regard to common trends in the field. The preponderance of published literature lacks rigorous quantitative evaluations of exoskeleton performance, making it difficult to determine the disadvantages and drawbacks of many of the devices. We analyzed common approaches in exoskeleton design and the convergence, or lack thereof, with certain technologies. We focused on actuators, sensors, energy sources, materials, and control strategies. One of the largest hurdles to be overcome in exoskeleton research is the user interface and control. More intuitive and flexible user interfaces are needed to increase the success of robotic exoskeletons. In the last section, we discuss promising future solutions to the major hurdles in exoskeleton control. A number of emerging technologies could deliver substantial advantages to existing and future exoskeleton designs. We conclude with a listing of the advantages and disadvantages of the emerging technologies and discuss possible futures for the field.

592 citations


Journal ArticleDOI
01 Aug 2017
TL;DR: Results demonstrated that the muscular effort and smoothness of tracking movements decreased with an increase in the assistant ratio, which implied that a more physiologically appropriate model could enable more natural and human-like human–robot cooperation and has potential value for improvement of human–exoskeleton interaction in future applications.
Abstract: Although the merits of electromyography (EMG)-based control of powered assistive systems have been certified, the factors that affect the performance of EMG-based human–robot cooperation, which are very important, have received little attention. This study investigates whether a more physiologically appropriate model could improve the performance of human–robot cooperation control for an ankle power-assist exoskeleton robot. To achieve the goal, an EMG-driven Hill-type neuromusculoskeletal model (HNM) and a linear proportional model (LPM) were developed and calibrated through maximum isometric voluntary dorsiflexion (MIVD). The two control models could estimate the real-time ankle joint torque, and HNM is more accurate and can account for the change of the joint angle and muscle dynamics. Then, eight healthy volunteers were recruited to wear the ankle exoskeleton robot and complete a series of sinusoidal tracking tasks in the vertical plane. With the various levels of assist based on the two calibrated models, the subjects were instructed to track the target displayed on the screen as accurately as possible by performing ankle dorsiflexion and plantarflexion. Two measurements, the root mean square error (RMSE) and root mean square jerk (RMSJ), were derived from the assistant torque and kinematic signals to characterize the movement performances, whereas the amplitudes of the recorded EMG signals from the tibialis anterior (TA) and the gastrocnemius (GAS) were obtained to reflect the muscular efforts. The results demonstrated that the muscular effort and smoothness of tracking movements decreased with an increase in the assistant ratio. Compared with LPM, subjects made lower physical efforts and generated smoother movements when using HNM, which implied that a more physiologically appropriate model could enable more natural and human-like human–robot cooperation and has potential value for improvement of human–exoskeleton interaction in future applications.

119 citations


Journal ArticleDOI
TL;DR: Evidence is provided supporting the use of wearable exoskeletons as a treatment strategy to improve walking in children with CP by showing that the exoskeleton reduced crouch in a cohort of ambulatory children withCP during overground walking.
Abstract: The ability to walk contributes considerably to physical health and overall well-being, particularly in children with motor disability, and is therefore prioritized as a rehabilitation goal. However, half of ambulatory children with cerebral palsy (CP), the most prevalent childhood movement disorder, cease to walk in adulthood. Robotic gait trainers have shown positive outcomes in initial studies, but these clinic-based systems are limited to short-term programs of insufficient length to maintain improved function in a lifelong disability such as CP. Sophisticated wearable exoskeletons are now available, but their utility in treating childhood movement disorders remains unknown. We evaluated an exoskeleton for the treatment of crouch (or flexed-knee) gait, one of the most debilitating pathologies in CP. We show that the exoskeleton reduced crouch in a cohort of ambulatory children with CP during overground walking. The exoskeleton was safe and well tolerated, and all children were able to walk independently with the device. Rather than guiding the lower limbs, the exoskeleton dynamically changed the posture by introducing bursts of knee extension assistance during discrete portions of the walking cycle, a perturbation that resulted in maintained or increased knee extensor muscle activity during exoskeleton use. Six of seven participants exhibited postural improvements equivalent to outcomes reported from invasive orthopedic surgery. We also demonstrate that improvements in crouch increased over the course of our multiweek exploratory trial. Together, these results provide evidence supporting the use of wearable exoskeletons as a treatment strategy to improve walking in children with CP.

97 citations


Journal ArticleDOI
01 Jun 2017
TL;DR: The design of and first results from a powered exoskeleton for extension assistance as a treatment for crouch gait in children with cerebral palsy are presented, establishing the initial feasibility of robotic exoskeletons for treatment of crouch.
Abstract: Crouch gait, a pathological pattern of walking characterized by excessive knee flexion, is one of the most common gait disorders observed in children with cerebral palsy (CP). Effective treatment of crouch during childhood is critical to maintain mobility into adulthood, yet current interventions do not adequately alleviate crouch in most individuals. Powered exoskeletons provide an untapped opportunity for intervention. The multiple contributors to crouch, including spasticity, contracture, muscle weakness, and poor motor control make design and control of such devices challenging in this population. To our knowledge, no evidence exists regarding the feasibility or efficacy of utilizing motorized assistance to alleviate knee flexion in crouch gait. Here, we present the design of and first results from a powered exoskeleton for extension assistance as a treatment for crouch gait in children with CP. Our exoskeleton, based on the architecture of a knee-ankle-foot orthosis, is lightweight (3.2 kg) and modular. On board sensors enable knee extension assistance to be provided during distinct phases of the gait cycle. We tested our device on one six-year-old male participant with spastic diplegia from CP. Our results show that the powered exoskeleton improved knee extension during stance by 18.1° while total knee range of motion improved 21.0°. Importantly, we observed no significant decrease in knee extensor muscle activity, indicating the user did not rely solely on the exoskeleton to extend the limb. These results establish the initial feasibility of robotic exoskeletons for treatment of crouch and provide impetus for continued investigation of these devices with the aim of deployment for long term gait training in this population.

82 citations


Journal ArticleDOI
01 Feb 2017
TL;DR: The Achilles exoskeleton is intended to provide push-off assistance for healthy subjects during walking by providing a series elastic actuator that has been optimized to provide maximal push- off power.
Abstract: This paper evaluates the Achilles exoskeleton. The exoskeleton is intended to provide push-off assistance for healthy subjects during walking. The assistance is provided by a series elastic actuator that has been optimized to provide maximal push-off power. The paper presents the control method of the exoskeleton and the evaluation of the exoskeleton.

65 citations


Journal ArticleDOI
TL;DR: Myoelectric control had more advantages (metabolic cost and muscle activity reduction) compared to a controller that targeted a biological torque profile for walking with a robotic hip exoskeleton, however, these results were obtained with a singleExoskeleton device with specific control configurations while level walking at a single speed.
Abstract: Background Despite a large increase in robotic exoskeleton research, there are few studies that have examined human performance with different control strategies on the same exoskeleton device. Direct comparison studies are needed to determine how users respond to different types of control. The purpose of this study was to compare user performance using a robotic hip exoskeleton with two different controllers: a controller that targeted a biological hip torque profile and a proportional myoelectric controller. Methods We tested both control approaches on 10 able-bodied subjects using a pneumatically powered hip exoskeleton. The state machine controller targeted a biological hip torque profile. The myoelectric controller used electromyography (EMG) of lower limb muscles to produce a proportional control signal for the hip exoskeleton. Each subject performed two 30-minute exoskeleton walking trials (1.0 m/s) using each controller and a 10-minute trial with the exoskeleton unpowered. During each trial, we measured subjects’ metabolic cost of walking, lower limb EMG profiles, and joint kinematics and kinetics (torques and powers) using a force treadmill and motion capture. Results Compared to unassisted walking in the exoskeleton, myoelectric control reduced metabolic cost by 13% (p=0.005) and biological hip torque control reduced metabolic cost by 7%. Subjects reduced muscle activity relative to the unpowered condition for a greater number of lower limb muscles using myoelectric control compared to the biological hip torque control. More subjects subjectively preferred the myoelectric controller to the biological hip torque control. Conclusions Myoelectric control had more advantages (metabolic cost and muscle activity reduction) compared to a controller that targeted a biological torque profile for walking with a robotic hip exoskeleton. However, these results were obtained with a single exoskeleton device with specific control configurations while level walking at a single speed. Further testing on different exoskeleton hardware and with more varied experimental protocols, such as testing over multiple types of terrain, is needed to fully elucidate the potential benefits of myoelectric control for exoskeleton technology.

62 citations


Journal ArticleDOI
11 Jan 2017
TL;DR: Results confirm the effectiveness of the WAKE-up design in providing torque assistance in accordance to the volitionalmovements especially in the recovery of correct foot landing at the start of the gait cycle.
Abstract: This paper presents the modular design and control of a novel compliant lower limbmulti-joint exoskeleton for the rehabilitation of ankle kneemobility and locomotion of pediatric patients with neurological diseases, such as Cerebral Palsy (CP). The device consists of an untethered powered knee–ankle–foot orthosis (KAFO), addressed as WAKE-up (Wearable Ankle Knee Exoskeleton), characterized by a position control and capable of operating synchronously and synergistically with the human musculoskeletal system. The WAKE-up mechanical system, control architecture and feature extraction are described. Two test benches were used to mechanically characterize the device. The full system showed a maximum value of hysteresis equal to 8.8% and a maximum torque of 5.6 N m/rad. A pre-clinical use was performed, without body weight support, by four typically developing children and three children with CP. The aims were twofold: 1) to test the structure under weight-bearing conditions and 2) to ascertain its ability to provide appropriate assistance to the ankle and the knee during overground walking in a real environment. Results confirm the effectiveness of the WAKE-up design in providing torque assistance in accordance to the volitionalmovements especially in the recovery of correct foot landing at the start of the gait cycle.

58 citations


Journal ArticleDOI
TL;DR: A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.
Abstract: Objective. Brain–machine interface (BMI) technologies have succeeded in controlling robotic exoskeletons, enabling some paralyzed people to control their own arms and hands. We have developed an exoskeleton asynchronously controlled by EEG signals. In this study, to enable real-time control of the exoskeleton for paresis, we developed a hybrid system with EEG and EMG signals, and the EMG signals were used to estimate its joint angles. Approach. Eleven able-bodied subjects and two patients with upper cervical spinal cord injuries (SCIs) performed hand and arm movements, and the angles of the metacarpophalangeal (MP) joint of the index finger, wrist, and elbow were estimated from EMG signals using a formula that we derived to calculate joint angles from EMG signals, based on a musculoskeletal model. The formula was exploited to control the elbow of the exoskeleton after automatic adjustments. Four able-bodied subjects and a patient with upper cervical SCI wore an exoskeleton controlled using EMG signals and were required to perform hand and arm movements to carry and release a ball. Main results. Estimated angles of the MP joints of index fingers, wrists, and elbows were correlated well with the measured angles in 11 able-bodied subjects (correlation coefficients were 0.81 ± 0.09, 0.85 ± 0.09, and 0.76 ± 0.13, respectively) and the patients (e.g. 0.91 ± 0.01 in the elbow of a patient). Four able-bodied subjects successfully positioned their arms to adequate angles by extending their elbows and a joint of the exoskeleton, with root-mean-square errors <6°. An upper cervical SCI patient, empowered by the exoskeleton, successfully carried a ball to a goal in all 10 trials. Significance. A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.

57 citations


Journal ArticleDOI
01 Jun 2017
TL;DR: This paper aims at adaptive identification of human motor intent, and proposed an iterative prediction-compensation motion control scheme for an exoskeleton knee joint that validated the effectiveness and ease of use of the proposed control scheme.
Abstract: Transparent control is still highly challenging for robotic exoskeletons, especially when a simple strategy is expected for a large-impedance device. To improve the transparency for late-phase rehabilitation when “patient-in-charge” mode is necessary, this paper aims at adaptive identification of human motor intent, and proposed an iterative prediction-compensation motion control scheme for an exoskeleton knee joint. Based on the analysis of human-machine interactive mechanism (HMIM) and the semiphenomenological biomechanical model of muscle, an online adaptive predicting controller is designed using a focused time-delay neural network (FTDNN) with the inputs of electromyography (EMG), position and interactive force, where the activation level of muscle is estimated from EMG using a novel energy kernel method. The compensating controller is designed using the normative force-position control paradigm. Initial experiments on the human–machine integrated knee system validated the effectiveness and ease of use of the proposed control scheme.

56 citations


Proceedings ArticleDOI
01 Jul 2017
TL;DR: The presented wrist module's performance and operational considerations support its use in a wide range of future clinical investigations and are quantified experimentally in terms of functional workspace and dynamic properties.
Abstract: Robotic devices have been clinically verified for use in long duration and high intensity rehabilitation needed for motor recovery after neurological injury. Targeted and coordinated hand and wrist therapy, often overlooked in rehabilitation robotics, is required to regain the ability to perform activities of daily living. To this end, a new coupled hand-wrist exoskeleton has been designed. This paper details the design of the wrist module and several human-related considerations made to maximize its potential as a coordinated hand-wrist device. The serial wrist mechanism has been engineered to facilitate donning and doffing for impaired subjects and to insure compatibility with the hand module in virtual and assisted grasping tasks. Several other practical requirements have also been addressed, including device ergonomics, clinician-friendliness, and ambidextrous reconfigurability. The wrist module's capabilities as a rehabilitation device are quantified experimentally in terms of functional workspace and dynamic properties. Specifically, the device possesses favorable performance in terms of range of motion, torque output, friction, and closed-loop position bandwidth when compared with existing devices. The presented wrist module's performance and operational considerations support its use in a wide range of future clinical investigations.

56 citations


Journal ArticleDOI
TL;DR: Although, exoskeletons are not yet an established treatment in the rehabilitation of spinal cord injuries, the devices will play a more important role in the future.

Proceedings ArticleDOI
01 Jul 2017
TL;DR: A hip joint exoskeleton to boost gait function in the elderly and rehabilitation of post-stroke patients and quantitatively evaluates the impact of the power and mass of theExoskeleton was found to be more effective on slopes than level ground in saving the metabolic cost.
Abstract: We have developed a hip joint exoskeleton to boost gait function in the elderly and rehabilitation of post-stroke patients. To quantitatively evaluate the impact of the power and mass of the exoskeleton, we measured the metabolic cost of walking on slopes of 0, 5, and 10% grade, once not wearing the exoskeleton and then wearing it. The exoskeleton reduced the metabolic cost by 13.5,15.5 and 9.8% (31.9, 51.6 and 45.6 W) at 0, 5, and 10% grade, respectively. The exoskeleton performance index was computed as 0.97, 1.24, and 1.24 at each grade, implicating that the hip exoskeleton was more effective on slopes than level ground in saving the metabolic cost.

Journal ArticleDOI
TL;DR: An advanced myoelectric pattern recognition scheme for real-time intention-driven control of a hand exoskeleton for neurological injury rehabilitation and shows great potential for improving hand function after neurological injuries.
Abstract: Robot-assisted training provides an effective approach to neurological injury rehabilitation. To meet the challenge of hand rehabilitation after neurological injuries, this study presents an advanced myoelectric pattern recognition scheme for real-time intention-driven control of a hand exoskeleton. The developed scheme detects and recognizes user's intention of six different hand motions using four channels of surface electromyography (EMG) signals acquired from the forearm and hand muscles, and then drives the exoskeleton to assist the user accomplish the intended motion. The system was tested with eight neurologically intact subjects and two individuals with spinal cord injury (SCI). The overall control accuracy was [Formula: see text] for the neurologically intact subjects and [Formula: see text] for the SCI subjects. The total lag of the system was approximately 250[Formula: see text]ms including data acquisition, transmission and processing. One SCI subject also participated in training sessions in his second and third visits. Both the control accuracy and efficiency tended to improve. These results show great potential for applying the advanced myoelectric pattern recognition control of the wearable robotic hand system toward improving hand function after neurological injuries.

Proceedings ArticleDOI
17 Jul 2017
TL;DR: The results showed the powered ankle dorsiflexion assistance could reduce dropped foot of the stroke patients in swing phase and provide better gait pattern.
Abstract: Lower Limb Exoskeleton robot that can facilitate stair walking is a big challenge, most systems could only provide level ground walking. In this study, a lightweight (0.5kg at ankle, 0.5kg at waist for control box) and autonomous exoskeleton Ankle Robot was proposed to provide power assistance for gait training of chronic stroke patients and it can facilitate three walking conditions in real-time: (1) level walking, (2) stair ascending, and (3) stair descending. Chronic stroke patients (n=3) with drop foot gait deficit and moderate motor impairment were recruited to evaluate the system under different walking conditions (Functional Ambulatory Category: FAC=4.7±0.5 and Fugl-Meyer Assessment for lower-extremity: FMA-LE=13.7±2.9). The system consisted of a specially designed carbon fiber AFO, servomotor, gear transmission system, IMU and force sensors, and control box. The IMU sensors embedded in the shank measured acceleration and angular velocity to identify distinct features in leg tilting angle and leg angular velocity between the three walking conditions. The results showed the powered ankle dorsiflexion assistance could reduce dropped foot of the stroke patients in swing phase and provide better gait pattern. A demo of the ankle robot will be conducted in the conference.

Proceedings ArticleDOI
Jusuk Lee1, Keehong Seo1, Bokman Lim1, Junwon Jang1, Kyungrock Kim1, Hyun Do Choi1 
01 Jul 2017
TL;DR: An assistance timing controller is introduced that regulates assistance timing such that peak joint velocity and peak assistance power are offset by a reference value for the authors' hip-type exoskeleton, and the manner in which various assistance timing references affect an important metric for performance, namely metabolic cost is measured.
Abstract: There are many important factors in developing an exoskeleton for assisting human locomotion. For example, the weight should be sufficiently light, the assist torque should be high enough to assist joint motion, and the assistance timing should be just right. Understanding how these design parameters affect overall performance of a complex human-machine system is critical for the development of these types of systems. The present study introduces an assistance timing controller that regulates assistance timing such that peak joint velocity and peak assistance power are offset by a reference value for our hip-type exoskeleton. This is followed by measuring the manner in which various assistance timing references affect an important metric for performance, namely metabolic cost. The results indicate that net metabolic cost exhibits a concave up pattern with the most reduction of 21%, when compared to walking without the exoskeleton, at 0% assistance timing reference. The study also examines assistance timing's effect on gait parameters; increase in assistance timing reference increases step length, decreases cadence, and increases walk ratio (i.e. step length/cadence ratio) during treadmill walking.

Proceedings ArticleDOI
01 Jul 2017
TL;DR: This paper details the design process and features of a novel upper limb rehabilitation exoskeleton named CLEVER (Compact, Low-weight, Ergonomic, Virtual/Augmented Reality Enhanced Rehabilitation) ARM.
Abstract: This paper details the design process and features of a novel upper limb rehabilitation exoskeleton named CLEVER (Compact, Low-weight, Ergonomic, Virtual/Augmented Reality Enhanced Rehabilitation) ARM. The research effort is focused on designing a lightweight and ergonomic upper-limb rehabilitation exoskeleton capable of producing diverse and perceptually rich training scenarios. To this end, the knowledge available in the literature of rehabilitation robotics is used along with formal conceptual design techniques. This paper briefly reviews the systematic approach used for design of the exoskeleton, and elaborates on the specific details of the proposed design concept and its advantages over other design possibilities. The kinematic structure of CLEVER ARM has eight degrees of freedom supporting the motion of shoulder girdle, glenohumeral joint, elbow and wrist. Six degrees of freedom of the exoskeleton are active, and the two degrees of freedom supporting the wrist motion are passive. Kinematics of the proposed design is studied analytically and experimentally with the aid of a 3D printed prototype. The paper is concluded by some remarks on the optimization of the design, motorization of device, and the fabrication challenges.

Journal ArticleDOI
TL;DR: This research presents a novel lightweight hand exoskeleton robot, called Advanced Service Robots laboratory (ASR) glove, which is shape memory alloy tendon-based actuated which can be utilized for both rehabilitation exercises and assistance for people with hand disability.
Abstract: To date, various hand exoskeleton devices have been proposed. Most of them, however, contain linkage mechanisms which are relatively weighty. This research presents a novel lightweight hand exoskel...

Proceedings ArticleDOI
01 Jul 2017
TL;DR: A tethered knee exoskeleton with a strong lightweight frame and comfortable, four-point contact with the leg is designed and built to investigate robotic assistance strategies to improve gait rehabilitation and enhance human athletic ability.
Abstract: Lower-limb exoskeletons show promise for improving gait rehabilitation for those with chronic gait abnormalities due to injury, stroke or other illness. We designed and built a tethered knee exoskeleton with a strong lightweight frame and comfortable, four-point contact with the leg. The device is structurally compliant in select directions, instrumented to measure joint angle and applied torque, and is lightweight (0.76 kg). The exoskeleton is actuated by two off-board motors. Closed loop torque control is achieved using classical proportional feedback control with damping injection in conjunction with iterative learning. We tested torque measurement accuracy and found root mean squared (RMS) error of 0.8 Nm with a max load of 62.2 Nm. Bandwidth was measured to be phase limited at 45 Hz when tested on a rigid test stand and 23 Hz when tested on a person's leg. During bandwidth tests peak extension torques were measured up to 50 Nm. Torque tracking was tested during walking on a treadmill at 1.25 m/s with peak flexion torques of 30 Nm. RMS torque tracking error averaged over a hundred steps was 0.91 Nm. We intend to use this knee exoskeleton to investigate robotic assistance strategies to improve gait rehabilitation and enhance human athletic ability.

Journal ArticleDOI
TL;DR: A five degrees-of-freedom (DoF) low inertia shoulder exoskeleton and a new method of motion coupling, which can be used to impose kinematic constraints on a wide variety of parallel architectures, are presented.
Abstract: This paper presents a five degrees-of-freedom (DoF) low inertia shoulder exoskeleton. This device is comprised of two novel technologies. The first is 3DoF spherical parallel manipulator (SPM), which was developed using a new method of parallel manipulator design. This method involves mechanically coupling certain DoF of each independently actuated linkage of the parallel manipulator in order to constrain the kinematics of the entire system. The second is a 2DoF passive slip interface used to couple the user upper arm to the SPM. This slip interface increases system mobility and prevents joint misalignment caused by the translational motion of the user’s glenohumeral joint from introducing mechanical interference. An experiment to validate the kinematics of the SPM was performed using motion capture. The results of this experiment validated the SPM’s forward and inverse kinematic solutions through an Euler angle comparison of the actual and command orientations. A computational slip model was created to quantify the passive slip interface response for different conditions of joint misalignment. In addition to offering a low inertia solution for the rehabilitation or augmentation of the human shoulder, this device demonstrates a new method of motion coupling, which can be used to impose kinematic constraints on a wide variety of parallel architectures. Furthermore, the presented device demonstrates a passive slip interface that can be used with either parallel or serial robotic systems. [DOI: 10.1115/1.4035087]

Journal ArticleDOI
TL;DR: The ETH Knee Perturbator can deliver safe, precisely timed, and controlled perturbations, which is a prerequisite for the estimation of knee joint impedance during gait.
Abstract: Objective: An improved understanding of mechanical impedance modulation in human joints would provide insights about the neuromechanics underlying functional movements. Experimental estimation of impedance requires specialized tools with highly reproducible perturbation dynamics and reliable measurement capabilities. This paper presents the design and mechanical characterization of the ETH Knee Perturbator: an actuated exoskeleton for perturbing the knee during gait. Methods: A novel wearable perturbation device was developed based on specific experimental objectives. Bench-top tests validated the device's torque limiting capability and characterized the time delays of the on-board clutch. Further tests demonstrated the device's ability to perform system identification on passive loads with static initial conditions. Finally, the ability of the device to consistently perturb human gait was evaluated through a pilot study on three unimpaired subjects. Results: The ETH Knee Perturbator is capable of identifying mass-spring systems within 15% accuracy, accounting for over 95% of the variance in the observed torque in 10 out of 16 cases. Five-degree extension and flexion perturbations were executed on human subjects with an onset timing precision of 2.52% of swing phase duration and a rise time of 36.5 ms. Conclusion: The ETH Knee Perturbator can deliver safe, precisely timed, and controlled perturbations, which is a prerequisite for the estimation of knee joint impedance during gait. Significance: Tools such as this can enhance models of neuromuscular control, which may improve rehabilitative outcomes following impairments affecting gait and advance the design and control of assistive devices.

Proceedings ArticleDOI
Charles Lambelet1, Mingxing Lyu1, Daniel Woolley1, Roger Gassert1, Nicole Wenderoth1 
01 Jan 2017
TL;DR: The eWrist is developed, a wearable one degree-of-freedom powered exoskeleton which supports wrist extension training and aims at providing a training device which enhances activity of the wrist extensor muscles in the context of daily life activities, thereby, driving cortical reorganization and recovery.
Abstract: Chronic wrist impairment is frequent following stroke and negatively impacts everyday life. Rehabilitation of the dysfunctional limb is possible but requires extensive training and motivation. Wearable training devices might offer new opportunities for rehabilitation. However, few devices are available to train wrist extension even though this movement is highly relevant for many upper limb activities of daily living. As a proof of concept, we developed the eWrist, a wearable one degree-of-freedom powered exoskeleton which supports wrist extension training. Conceptually one might think of an electric bike which provides mechanical support only when the rider moves the pedals, i.e. it enhances motor activity but does not replace it. Stroke patients may not have the ability to produce overt movements, but they might still be able to produce weak muscle activation that can be measured via surface electromyography (sEMG). By combining force and sEMG-based control in an assist-as-needed support strategy, we aim at providing a training device which enhances activity of the wrist extensor muscles in the context of daily life activities, thereby, driving cortical reorganization and recovery. Preliminary results show that the integration of sEMG signals in the control strategy allow for adjustable assistance with respect to a proxy measurement of corticomotor drive.

Proceedings ArticleDOI
01 Jul 2017
TL;DR: TWIICE provides complete mobilization of the lower-limbs, which is a first step toward enabling the user to regain independence in activities of the daily living.
Abstract: This paper introduces TWIICE, a lower-limb exoskeleton that enables people suffering from complete paraplegia to stand up and walk again. TWIICE provides complete mobilization of the lower-limbs, which is a first step toward enabling the user to regain independence in activities of the daily living. The tasks it can perform include level and inclined walking (up to 20° slope), stairs ascent and descent, sitting on a seat, and standing up. Participation in the world's first Cybathlon (Zurich, 2016) demonstrated good performance at these demanding tasks. In this paper, we describe the implementation details of the device and comment on preliminary results from a single user case study.

Journal ArticleDOI
05 Jun 2017-Sensors
TL;DR: A novel design of a multi-axis force sensor dedicated for measuring pelvis interaction forces in a rehabilitation exoskeleton device and two of the developed sensors are integrated and tested in a complex gait rehabilitation device for safe and compliant control.
Abstract: Human–robot interaction sensing is a compulsory feature in modern robotic systems where direct contact or close collaboration is desired. Rehabilitation and assistive robotics are fields where interaction forces are required for both safety and increased control performance of the device with a more comfortable experience for the user. In order to provide an efficient interaction feedback between the user and rehabilitation device, high performance sensing units are demanded. This work introduces a novel design of a multi-axis force sensor dedicated for measuring pelvis interaction forces in a rehabilitation exoskeleton device. The sensor is conceived such that it has different sensitivity characteristics for the three axes of interest having also movable parts in order to allow free rotations and limit crosstalk errors. Integrated sensor electronics make it easy to acquire and process data for a real-time distributed system architecture. Two of the developed sensors are integrated and tested in a complex gait rehabilitation device for safe and compliant control.

Journal ArticleDOI
26 Jan 2017
TL;DR: A lower-limb exoskeleton controlled by the intracortical activity of an awake behaving rhesus macaque is presented as a proof-of-concept for a locomotorBMI, demonstrating the device’s capability to fulfill the demanding needs of this application.
Abstract: Recent advances in the field of brain–machine interfaces (BMIs) have demonstrated enormous potential to shape the future of rehabilitation and prosthetic devices. Here, a lower-limb exoskeleton controlled by the intracortical activity of an awake behaving rhesus macaque is presented as a proof-of-concept for a locomotorBMI. A detailed description of the mechanical device, including its innovative features and first experimental results, is provided. During operation, BMI-decoded position and velocity are directly mapped onto the bipedal exoskeleton’s motions, which then move the monkey’s legs as the monkey remains physicallypassive. To meet the unique requirements of such an application, the exoskeleton’s features include: high output torque with backdrivable actuation, size adjustability, and safe user–robot interface. In addition, a novel rope transmission is introduced and implemented. To test the performance of the exoskeleton, a mechanical assessment was conducted, which yielded quantifiable results for transparency, efficiency, stiffness, and tracking performance. Usage under both brain control and automated actuation demonstrates the device’s capability to fulfill the demanding needs of this application. These results lay the groundwork for further advancement in BMI-controlled devices for primates including humans.

Proceedings ArticleDOI
01 Jul 2017
TL;DR: The design of the battery-powered, self-contained exoskeleton intended to enable or facilitate bimanual activities of daily living (ADLs) for individuals with chronic upper extremity hemiparesis resulting from stroke is described and the results of initial testing with a single subject with hemiparedis from stroke are presented.
Abstract: This paper presents the design of a hand exoskeleton intended to enable or facilitate bimanual activities of daily living (ADLs) for individuals with chronic upper extremity hemiparesis resulting from stroke. The paper describes design of the battery-powered, self-contained exoskeleton and presents the results of initial testing with a single subject with hemiparesis from stroke. Specifically, an experiment was conducted requiring the subject to repeatedly remove the lid from a water bottle both with and without the hand exoskeleton. The relative times required to remove the lid from the bottles was considerably lower when using the exoskeleton. Specifically, the average amount of time required to grasp the bottle with the paretic hand without the exoskeleton was 25.9 s, with a standard deviation of 33.5 s, while the corresponding average amount of time required to grasp the bottle with the exoskeleton was 5.1 s, with a standard deviation of 1.9 s. Thus, the task time involving the paretic hand was reduced by a factor of five, while the standard deviation was reduced by a factor of 16.

Proceedings ArticleDOI
01 Jul 2017
TL;DR: An arm rehabilitation system developed within the European project RETRAINER consists of a passive 4-degrees-of-freedom exoskeleton equipped with springs to provide gravity compensation and electromagnetic brakes to hold target positions and FES is integrated in the system to provide additional support to the most impaired muscles.
Abstract: The combined use of Functional Electrical Stimulation (FES) and robotic technologies is advocated to improve rehabilitation outcomes after stroke. This work describes an arm rehabilitation system developed within the European project RETRAINER. The system consists of a passive 4-degrees-of-freedom exoskeleton equipped with springs to provide gravity compensation and electromagnetic brakes to hold target positions. FES is integrated in the system to provide additional support to the most impaired muscles. FES is triggered based on the volitional EMG signal of the same stimulated muscle; in order to encourage the active involvement of the patient the volitional EMG is also monitored throughout the task execution and based on it a happy or sad emoji is visualized at the end of each task. The control interface control of the system provides a GUI and multiple software tools to organize rehabilitation exercises and monitor rehabilitation progress. The functionality and the usability of the system was evaluated on four stroke patients. All patients were able to use the system and judged positively its wearability and the provided support. They were able to trigger the stimulation based on their residual muscle activity and provided different levels of active involvement in the exercise, in agreement with their level of impairment. A randomized controlled trial aimed at evaluating the effectiveness of the RETRAINER system to improve arm function after stroke is currently ongoing.

Journal ArticleDOI
09 Jun 2017
TL;DR: The resistance range according to the degree of spasticity should be considered when designing practical neurorehabilitation robots.
Abstract: Spasticity is an important factor in designing wearable and lightweight exoskeleton neurorehabilitation robots. The proposed study evaluates biomechanical reactions of an exoskeleton robot to spasticity and establishes relevant guidelines for robot design. A two-axis exoskeleton robot is used to evaluate a group of 20 patients post-stroke with spastic elbow and/or wrist joints. All subjects are given isokinetic movements at various angular velocities within the capable range of motion for both joints. The resistance torque and corresponding angular position at each joint are recorded continuously. Maximal resistance torques caused by low (modified Ashworth scale (MAS) 0, 1), intermediate (MAS 1+), and high (MAS 2 and 3) grade spasticity were 3.68 ± 2.42, 5.94 ± 2.55, and 8.25 ± 3.35 Nm for the elbow flexor ( ${p} , between each grades) and 4.23 ± 1.75, 5.68 ± 1.96, and 5.44 ± 2.02 Nm for the wrist flexor ( ${p} , for low versus intermediate, low versus high grade spasticity). The angular velocity did not significantly influence maximal resistance torque in either joint. The catch occurred more quickly at higher velocities for low and intermediate elbow flexor spasticity ( ${p} ). Spasticity caused considerable resistance to the robots during mechanically actuated movements. The resistance range according to the degree of spasticity should be considered when designing practical neurorehabilitation robots.

Proceedings ArticleDOI
01 Jul 2017
TL;DR: To customize the hand exoskeleton for the user, the polynomial curve was adjusted to the joint range of motion (ROM) of the user and the optimal design of theExoskeleton structure was obtained using the optimization algorithm.
Abstract: In this paper, design of a wearable hand exoskeleton system for exercising flexion/extension of the fingers, is proposed. The exoskeleton was designed with a simple and wearable structure to aid finger motions in 1 degree of freedom (DOF). A hand grasping experiment by fully-abled people was performed to investigate general hand flexion/extension motions and the polynomial curve of general hand motions was obtained. To customize the hand exoskeleton for the user, the polynomial curve was adjusted to the joint range of motion (ROM) of the user and the optimal design of the exoskeleton structure was obtained using the optimization algorithm. A prototype divided into two parts (one part for the thumb, the other for rest fingers) was actuated by only two linear motors for compact size and light weight.

Journal ArticleDOI
TL;DR: The static workspace of the exoskeleton is large enough to meet the demand of assisting aged and disabled individuals in completing most of their activities of daily living (ADLs) and has a stronger carrying capacity.
Abstract: BACKGROUND Many countries, including Japan, Italy, and China are experiencing demographic shifts as their populations age. Some basic activities of daily living (ADLs) are difficult for elderly people to complete independently due to declines in motor function. OBJECTIVE In this paper, a 6-DOF wearable cable-driven upper limb exoskeleton (CABexo) based on epicyclic gear trains structure is proposed. METHODS The main structure of the exoskeleton system is composed of three epicyclic gear train sections. This new exoskeleton has a parallel mechanical structure to the traditional serial structure, but is stiffer and has a stronger carrying capacity. The traditional gear transmission structure is replaced with a cable transmission system, which is quieter, and has higher accuracy and smoother transmission. RESULTS AND CONCLUSIONS The static workspace of the exoskeleton is large enough to meet the demand of assisting aged and disabled individuals in completing most of their activities of daily living (ADLs).

Proceedings ArticleDOI
01 Jul 2017
TL;DR: The evaluation of an exoskeleton designed for assisting individuals to rehabilitate compromised lower limb movements resulting from stroke or incomplete spinal cord injury, composed of lightweight tubular structures and six free joints that provide a modular feature to the system is dealt with.
Abstract: This paper deals with the evaluation of an exoskeleton designed for assisting individuals to rehabilitate compromised lower limb movements resulting from stroke or incomplete spinal cord injury. The exoskeleton is composed of lightweight tubular structures and six free joints that provide a modular feature to the system. This feature allows the exoskeleton to be adapted to assist the movement of one or more patient joints. The actuation of the exoskeleton is also modular, and can be performed passively, by means of springs and dampers, or actively through actuators. In addition, its telescopic tubular links, developed to adjust the size of the links in order to align the joints of the exoskeleton with patient joints, allows the exoskeleton to be adjustable to fit different patients. Experiments considering the interaction between a healthy subject and the exoskeleton are performed to evaluate the influence of the exoskeleton structure on kinematic and muscular activity profiles during walking.