scispace - formally typeset
Book ChapterDOI

Quantitation of protein.

Christa M. Stoscheck
- 01 Jan 1990 - 
- Vol. 182, pp 50-68
Reads0
Chats0
TLDR
This chapter discusses various methods of estimating protein concentration as defined by the difference in energy between the orbital of the unexcited electron and a higher energy orbital.
Abstract
Publisher Summary This chapter discusses various methods of estimating protein concentration. Absorption spectroscopy involves the absorption of a photon by an electron. Only those photons with a certain energy level can be absorbed as defined by the difference in energy between the orbital of the unexcited electron and a higher energy orbital. The peptide bond absorbs photons below 210 nm. Because of the large number of peptide bonds in a protein, this is a highly sensitive area of the protein spectrum. Although protein conformation and some absorption by tryptophan and tyrosine residues occurs in this region, less variability between proteins is observed than at 280 nm. There is a need to avoid storing buffers in plastic containers because some plastics leach plasticizers, which absorb at ultraviolet (UV) wavelengths. Detergents can also be troublesome because many absorb UV light. If the buffer or protein solution is cold, the outside of the cuvette may need to be wiped between each reading with a lint-free wiper and the readings should be made quickly after placing the cold solution into the cuvette, because atmospheric moisture may condense on the outside of the cuvette producing an erroneously high reading.

read more

Citations
More filters
Journal ArticleDOI

HLA class I heavy-chain gene promoter elements mediating synergy between tumor necrosis factor and interferons.

TL;DR: Observations suggest that synergy between TNF and IFNs in the induction of HLA class I gene expression results from the sum of individual interactions of cytokine-activated enhancer-binding factors with the transcription initiation complex.
Journal ArticleDOI

Assays for determination of protein concentration.

TL;DR: In this article, the authors describe how to perform commonly used protein assays, e.g., Lowry, Bradford, BCA, and UV spectroscopic, and emphasize sample and buffer compatibility.
Journal ArticleDOI

A comparison of Lowry, Bradford and Smith protein assays using different protein standards and protein isolated from the marine diatom Thalassiosira pseudonana

TL;DR: It remains unclear which spectrophotometric assay is most accurate, but the Bradford assay is faster and simpler, and is less likely to be affected by non-protein compounds found in marine phytoplankton.
Journal ArticleDOI

Platinum Nanoparticle Modified Polyaniline-Functionalized Boron Nitride Nanotubes for Amperometric Glucose Enzyme Biosensor

TL;DR: The developed glucose biosensor displayed high sensitivity and stability, good reproducibility, anti-interference ability, especially excellent acid stability and heat resistance, indicate great promising application in numerous industrial and biotechnological operations involving harsh conditions.
Journal ArticleDOI

Spectrophotometric Determination of Protein Concentration

TL;DR: A basic protocol describes how to measure the concentration of a protein using the calculated ɛ and the Beer‐Lambert law, and a sensitive and simple method are provided for estimating total protein concentration in crude extracts.
References
More filters
Journal Article

Protein Measurement with the Folin Phenol Reagent

TL;DR: Procedures are described for measuring protein in solution or after precipitation with acids or other agents, and for the determination of as little as 0.2 gamma of protein.
Journal ArticleDOI

A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding

TL;DR: This assay is very reproducible and rapid with the dye binding process virtually complete in approximately 2 min with good color stability for 1 hr with little or no interference from cations such as sodium or potassium nor from carbohydrates such as sucrose.
PatentDOI

Measurement of protein using bicinchoninic acid

TL;DR: This new method maintains the high sensitivity and low protein-to-protein variation associated with the Lowry technique and demonstrates a greater tolerance of the bicinchoninate reagent toward such commonly encountered interferences as nonionic detergents and simple buffer salts.
Book

Methods of Enzymatic Analysis

TL;DR: Methods of enzymatic analysis, Methods of enzymes analysis, the authors, Methods of enzyme analysis, enzymatics, methods of enzymes, and methods of analysis, method of enzymes.
Journal ArticleDOI

A modification of the Lowry procedure to simplify protein determination in membrane and lipoprotein samples

TL;DR: The original Lowry method of protein determination has been modified by the addition of sodium dodecyl sulfate in the alkali reagent and an increase in the amount of copper tartrate reagent to be used with membrane and lipoprotein preparations without prior solubilization or lipid extraction.
Related Papers (5)