Sensitivity of direct versus concentrated sputum smear microscopy in HIV-infected patients suspected of having pulmonary tuberculosis

TLDR
Sputum concentration did not increase the sensitivity of light microscopy for TB diagnosis in this HIV-infected population and additional studies using maximal blinding, high-quality direct microscopy, and a rigorous gold standard should be conducted before universally recommending this technique.
Abstract
Sputum concentration increases the sensitivity of smear microscopy for the diagnosis of tuberculosis (TB), but few studies have investigated this method in human immunodeficiency virus (HIV)-infected individuals. We performed a prospective, blinded evaluation of direct and concentrated Ziehl-Neelsen smear microscopy on a single early-morning sputum sample in HIV-infected patients with > 2 weeks of cough hospitalized in Kampala, Uganda. Direct and concentrated smear results were compared with results of Lowenstein-Jensen culture. Of 279 participants, 170 (61%) had culture-confirmed TB. The sensitivity of direct and concentrated smear microscopy was not significantly different (51% vs. 52%, difference 1%, 95% confidence interval (CI): [-7%, 10%], p = 0.88). However, when results of both direct and concentrated smears were considered together, sensitivity was significantly increased compared with either method alone (64%, 95% CI: [56%, 72%], p < 0.01 for both comparisons) and was similar to that of direct smear results from consecutive (spot and early-morning) specimens (64% vs. 63%, difference 1%, 95% CI: [-6%, 8%], p = 0.85). Among 109 patients with negative cultures, one had a positive direct smear and 12 had positive concentrated smears (specificity 99% vs. 89%, difference 10%, 95% CI: [2%, 18%], p = 0.003). Of these 13 patients, 5 (38%) had improved on TB therapy after two months. Sputum concentration did not increase the sensitivity of light microscopy for TB diagnosis in this HIV-infected population. Given the resource requirements for sputum concentration, additional studies using maximal blinding, high-quality direct microscopy, and a rigorous gold standard should be conducted before universally recommending this technique.

read more

Content maybe subject to copyright    Report

Citations
More filters

A Technical Supplement: Reducing the Global Burden of Tuberculosis: The Contribution of Improved Diagnostics

TL;DR: It is found that a variety of new tests could help better identify TB cases and target treatment, thereby reducing the burden of disease.
Journal ArticleDOI

Diagnosis & treatment of tuberculosis in HIV co-infected patients

TL;DR: An overview of existing diagnostic strategies, new tests in the pipeline and recommendations for treatment of patients with HIV-TB dual infection is presented.
Journal ArticleDOI

Host-response-based gene signatures for tuberculosis diagnosis: A systematic comparison of 16 signatures.

TL;DR: It is found that host-response-based diagnostics could accurately identify patients with ATB and predict individuals with high risk of progression from LTBI to ATB prior to sputum conversion.
Journal ArticleDOI

The Diagnostic Performance of the GenoType MTBDRplus Version 2 Line Probe Assay Is Equivalent to That of the Xpert MTB/RIF Assay

TL;DR: The detection of M. tuberculosis in culture-negative specimens confirmed that molecular assays should not be used for treatment monitoring, and the GenoType MTBDRplus (v2.0) assay will complement the Xpert MTB/RIF screening assay by validating rifampin susceptibility and providing information on isoniazid susceptibility.
Journal ArticleDOI

HIV-Associated Tuberculosis: Clinical Update

TL;DR: Because of the poor performance of sputum smear microscopy in HIV-infected patients, more sensitive tests-such as liquid culture systems, nucleic acid amplification assays, and detection of mycobacterial products in various body fluids-are being investigated.
References
More filters
Journal ArticleDOI

The growing burden of tuberculosis: global trends and interactions with the HIV epidemic.

TL;DR: The prevention of HIV and TB, the extension of WHO DOTS programs, and a focused effort to control HIV-related TB in areas of high HIV prevalence are matters of great urgency.
Journal ArticleDOI

Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative

TL;DR: If medical journals adopt the STARD checklist and flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public.
Journal ArticleDOI

Power and sample size calculations. A review and computer program.

TL;DR: In this article, the sample size and power equations for these designs are shown to be special cases of two generic formulae for sample sizes and power calculations, and a computer program is available that can be used for studies with dichotomous, continuous, or survival response measures.
Journal ArticleDOI

Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.

TL;DR: If medical journals adopt the STARD checklist and flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public.
Journal ArticleDOI

Transmission of Mycobacterium tuberculosis from patients smear-negative for acid-fast bacilli

TL;DR: In San Francisco, the acid-fast-bacilli smear identifies the most infectious patients, but patients with smear-negative culture-positive tuberculosis appear responsible for about 17% of tuberculosis transmission.
Related Papers (5)