scispace - formally typeset
Journal ArticleDOI

Statistics of atomic frequency standards

Reads0
Chats0
TLDR
In this paper, a theoretical analysis of the relationship between the expectation value of the standard deviation of the frequency fluctuations for any finite number of data samples and the infinite time average value of a standard deviation is presented.
Abstract
A theoretical development is presented which results in a relationship between the expectation value of the standard deviation of the frequency fluctuations for any finite number of data samples and the infinite time average value of the standard deviation, which provides an invariant measure of an important quality factor of a frequency standard. A practical and straightforward method of determining the power spectral density of the frequency fluctuations from the variance of the frequency fluctuations, the sampling time, the number of samples taken, and the dependence on system bandwidth is also developed. Additional insight is also given into some of the problems that arise from the presence of "flicker noise" (spectrum proportional to |ω|-1) modulation of the frequency of an oscillator. The theory is applied in classifying the types of noise on the signals of frequency standards made available at NBS, Boulder Laboratories, such as: masers (both H and N15H 3 ), the cesium beam frequency standard employed as the U. S. Frequency Standard, and rubidium gas cells. "Flicker noise" frequency modulation was not observed on the signals of masers for sampling times ranging from 0.1 second to 4 hours. In a comparison between the NBS hydrogen maser and the NBS III cesium beam, uncorrelated random noise was observed on the frequency fluctuations for sampling times extending to 4 hours; the fractional standard deviations of the frequency fluctuations were as low as 5 parts in 1014.

read more

Citations
More filters
Journal Article

High signal-to-noise ratio laser technique for accurate measurements of spectral line parameters

TL;DR: In this paper, a line-shape analysis with high-bandwidth locking of a continuous wave probe laser and the frequency-stabilized cavity ring-down spectroscopy technique is described, which yields high-resolution spectra with a relatively wide dynamic range and low detection limit.
Journal ArticleDOI

Effect of Dead-Time on the Estimation of the Two-Sample Variance

TL;DR: In this article, the effect of dead time on the precision of the time domain measure of frequency stability, in the presence of a limited number of data, was investigated and the possibility to distinguish between white and flicker noises was pointed out.
Journal ArticleDOI

High precision saturation spectroscopy of 127I2 with argon lasers at 5 145 Å and 5 017 Å : I — Main resonances

TL;DR: In this article, the authors present results on the hyperfine spectroscopy of 127I2 obtained with argon lasers and describe a saturated absorption or dispersion spectrometer and discuss the pressure dependence of the saturation line shapes.
Posted ContentDOI

Heart Rate Variability: Measures and Models

TL;DR: In this paper, various measures of the fluctuations of the sequence of intervals between beats of the human heart, and how such fluctuations can be used to assess the presence or likelihood of cardiovascular disease were examined.
References
More filters
Journal ArticleDOI

An Introduction to Fourier Analysis and Generalized Functions.

TL;DR: The theory of generalised functions and their Fourier transforms is discussed in this paper. But the analysis of Fourier transform is limited to the case of generalized functions, and it is not suitable for generalised function analysis.
Journal ArticleDOI

Some aspects of the theory and measurement of frequency fluctuations in frequency standards

TL;DR: In this article, the effects of finite observation time on the frequency and phase stability of a servo-controlled oscillator with respect to a given quartz oscillator and an atomic reference are analyzed.
Journal ArticleDOI

Atomic timekeeping and the statistics of precision signal generators

TL;DR: In this paper, a detailed analysis of the calibration procedure showed that the third finite difference of the phase is closely related to the clock errors and that quartz crystal oscillators exhibit a "flicker" or |ω|-1type of noise modulating the frequency of the oscillator.

Atomic timekeeping and the statistics of precision signal generators

TL;DR: The method of finite differences of the phase is shown to be a powerful means of classifying the statistical fluctuations of thephase and frequency for signal generators in general and by employing finite differences it is possible to avoid divergences normally associated with flicker noise spectra.
Related Papers (5)