scispace - formally typeset
Journal ArticleDOI

Statistics of atomic frequency standards

Reads0
Chats0
TLDR
In this paper, a theoretical analysis of the relationship between the expectation value of the standard deviation of the frequency fluctuations for any finite number of data samples and the infinite time average value of a standard deviation is presented.
Abstract
A theoretical development is presented which results in a relationship between the expectation value of the standard deviation of the frequency fluctuations for any finite number of data samples and the infinite time average value of the standard deviation, which provides an invariant measure of an important quality factor of a frequency standard. A practical and straightforward method of determining the power spectral density of the frequency fluctuations from the variance of the frequency fluctuations, the sampling time, the number of samples taken, and the dependence on system bandwidth is also developed. Additional insight is also given into some of the problems that arise from the presence of "flicker noise" (spectrum proportional to |ω|-1) modulation of the frequency of an oscillator. The theory is applied in classifying the types of noise on the signals of frequency standards made available at NBS, Boulder Laboratories, such as: masers (both H and N15H 3 ), the cesium beam frequency standard employed as the U. S. Frequency Standard, and rubidium gas cells. "Flicker noise" frequency modulation was not observed on the signals of masers for sampling times ranging from 0.1 second to 4 hours. In a comparison between the NBS hydrogen maser and the NBS III cesium beam, uncorrelated random noise was observed on the frequency fluctuations for sampling times extending to 4 hours; the fractional standard deviations of the frequency fluctuations were as low as 5 parts in 1014.

read more

Citations
More filters
Journal ArticleDOI

Frequency stability of a wavelength meter and applications to laser frequency stabilization.

TL;DR: This apparatus is used to demonstrate frequency control of a near-infrared laser, where a frequency instability below 3×10(-10) from 1 to 2000 s is achieved and is adequate for ion trapping and atom cooling experiments.
Journal ArticleDOI

Detection and identification of atomic clock anomalies

TL;DR: In this article, the authors developed a method that uses the dynamic Allan variance and the spectrogram to detect and to identify the typical anomalies of an atomic clock, and applied the method to simulated data.
Journal ArticleDOI

Refractometer for tracking changes in the refractive index of air near 780 nm

TL;DR: In this paper, a double-channel Fabry-Perot etalon and laser diodes emitting around 780 nm were used to measure the air-refractive index with an experimental uncertainty of 2 × 10-8.
Journal ArticleDOI

Simultaneous stabilization of the frequency and power of an AlGaAs semiconductor laser by use of the optogalvanic effect of krypton

TL;DR: In this paper, the frequency of an AlGaAs semiconductor laser operated in the 0.77 μm region has been locked to the optogalvanic signal of Kr I at 7694.5401 A. The power level adjustability at the frequency-locked state has been discussed.
Journal ArticleDOI

Geocentre motion measured with DORIS and SLR, and predicted by geophysical models

TL;DR: In this paper, the spectral signature of the non-seasonal components was analyzed and compared under two viewpoints: the amplitudes and phases of the seasonal components, and the spectral signatures of the spectral properties of the not-seasonally consistent components.
References
More filters
Journal ArticleDOI

An Introduction to Fourier Analysis and Generalized Functions.

TL;DR: The theory of generalised functions and their Fourier transforms is discussed in this paper. But the analysis of Fourier transform is limited to the case of generalized functions, and it is not suitable for generalised function analysis.
Journal ArticleDOI

Some aspects of the theory and measurement of frequency fluctuations in frequency standards

TL;DR: In this article, the effects of finite observation time on the frequency and phase stability of a servo-controlled oscillator with respect to a given quartz oscillator and an atomic reference are analyzed.
Journal ArticleDOI

Atomic timekeeping and the statistics of precision signal generators

TL;DR: In this paper, a detailed analysis of the calibration procedure showed that the third finite difference of the phase is closely related to the clock errors and that quartz crystal oscillators exhibit a "flicker" or |ω|-1type of noise modulating the frequency of the oscillator.

Atomic timekeeping and the statistics of precision signal generators

TL;DR: The method of finite differences of the phase is shown to be a powerful means of classifying the statistical fluctuations of thephase and frequency for signal generators in general and by employing finite differences it is possible to avoid divergences normally associated with flicker noise spectra.
Related Papers (5)