B
Brett E. Bouma
Researcher at Harvard University
Publications - 496
Citations - 52032
Brett E. Bouma is an academic researcher from Harvard University. The author has contributed to research in topics: Optical coherence tomography & Laser. The author has an hindex of 116, co-authored 474 publications receiving 49561 citations. Previous affiliations of Brett E. Bouma include Hope College & Lahey Hospital & Medical Center.
Papers
More filters
Journal ArticleDOI
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
Johannes F. de Boer,Barry Cense,B. Hyle Park,Mark C. Pierce,Guillermo J. Tearney,Brett E. Bouma +5 more
TL;DR: A signal-to-noise ratio (SNR) analysis is presented for optical coherence tomography (OCT) signals in which time-domain performance is compared with that of the spectral domain.
Journal ArticleDOI
Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation.
Guillermo J. Tearney,Evelyn Regar,Takashi Akasaka,Tom Adriaenssens,Peter Barlis,Hiram G. Bezerra,Brett E. Bouma,Nico Bruining,Jin-man Cho,Saqib Chowdhary,Marco A. Costa,Ranil de Silva,Jouke Dijkstra,Carlo Di Mario,Darius Dudeck,Erlin Falk,Marc D. Feldman,Peter J. Fitzgerald,Hector Garcia Garcia,Nieves Gonzalo,Juan F. Granada,Giulio Guagliumi,Niels Ramsing Holm,Yasuhiro Honda,Fumiaki Ikeno,Masanori Kawasaki,Janusz Kochman,Lukasz Koltowski,Takashi Kubo,Teruyoshi Kume,Hiroyuki Kyono,Cheung Chi Simon Lam,Guy Lamouche,David P. Lee,Martin B. Leon,Akiko Maehara,Olivia Manfrini,Gary S. Mintz,Kyiouchi Mizuno,Marie-Angèle Morel,Seemantini K. Nadkarni,Hiroyuki Okura,Hiromasa Otake,Arkadiusz Pietrasik,Francesco Prati,Lorenz Räber,Maria D. Radu,Johannes Rieber,Maria Riga,Andrew M. Rollins,Mireille Rosenberg,Vasile Sirbu,Patrick W. Serruys,Kenei Shimada,Toshiro Shinke,Junya Shite,Eliot Siegel,Shinjo Sonada,Melissa J. Suter,Shigeho Takarada,Atsushi Tanaka,Mitsuyasu Terashima,Thim Troels,Shiro Uemura,Giovanni J. Ughi,Heleen M.M. van Beusekom,Antonius F.W. van der Steen,Gerrit-Ann van Es,Gijs van Soest,Renu Virmani,Sergio Waxman,Neil J. Weissman,Giora Weisz +72 more
TL;DR: This document may be broadly used as a standard reference regarding the current state of theIVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVO CT data.
Journal ArticleDOI
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Guillermo J. Tearney,Mark E. Brezinski,Mark E. Brezinski,Brett E. Bouma,Brett E. Bouma,Stephen A. Boppart,Stephen A. Boppart,Costas Pitris,Costas Pitris,James F. Southern,James F. Southern,James G. Fujimoto,James G. Fujimoto +12 more
TL;DR: Optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter, and was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.
Journal Article
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Guillermo J. Tearney,Mark E. Brezinski,Brett E. Bouma,Stephen A. Boppart,Costas Pitris,James F. Southern,James G. Fujimoto +6 more
TL;DR: In this article, optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter, which was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.
Journal ArticleDOI
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Hiroshi Yabushita,Brett E. Bouma,Stuart L. Houser,H. Thomas Aretz,Ik-Kyung Jang,Kelly Schlendorf,Christopher R. Kauffman,Milen Shishkov,Dong-Heon Kang,Elkan F. Halpern,Guillermo J. Tearney +10 more
TL;DR: Objective OCT criteria are highly sensitive and specific for characterizing different types of atherosclerotic plaques in vitro and will provide a basis for the interpretation of intracoronary OCT images obtained from patients.