scispace - formally typeset
Journal ArticleDOI

Sample size and optimal designs for reliability studies

TLDR
A functional approximation to earlier exact results is shown to have excellent agreement with the exact results and one can use it easily without intensive numerical computation.
Abstract
A method is developed to calculate the required number of subjects k in a reliability study, where reliability is measured using the intraclass correlation rho. The method is based on a functional approximation to earlier exact results. The approximation is shown to have excellent agreement with the exact results and one can use it easily without intensive numerical computation. Optimal design configurations are also discussed; for reliability values of about 40 per cent or higher, use of two or three observations per subject will minimize the total number of observations required.

read more

Citations
More filters
Journal ArticleDOI

Validity and reproducibility of the 3D VECTRA photogrammetric surface imaging system for the maxillofacial anthropometric measurement on cleft patients

TL;DR: Measurements obtained from this 3D imaging system are valid and reproducible for evaluating CLP patients and are suitable to be used in a clinical setting for cleft patients.
Journal ArticleDOI

The Japanese Orthopedic Association Back Pain Evaluation Questionnaire (JOABPEQ): A validation of the reliability of the Thai version.

TL;DR: The Thai version of JOABPEQ had satisfactory internal consistency, test-retest reliability, and construct validity; it can be used as a reliable tool for assessing quality of life for lumbar spinal disease patients in Thailand.
Journal ArticleDOI

Evaluation of the precision and accuracy of the DIPA software postural assessment protocol

TL;DR: The results of the DIPA software were excellent, with no significant difference, random error and similar variance between measurements, compared to X-ray examination.
Journal ArticleDOI

Measurement of glenohumeral joint translation using real-time ultrasound imaging: A physiotherapist and sonographer intra-rater and inter-rater reliability study.

TL;DR: The ultrasound method was reliable for repeated measurement of both anterior and posterior glenohumeral translations with posterior measurements being more reliable than anterior.
Journal ArticleDOI

A Novel Technique for the Semi-Automated Measurement of Embryo Volume: An Intraobserver Reliability Study

TL;DR: The new semi-automated 3-D technique of embryo volumetry provides reliable measures of embryo volume and regression analysis showed good correlation between embryoVolume and CRL, confirming excellent intraobserver agreement.
Related Papers (5)
Trending Questions (1)
What is the optimal sample size for DA?

The optimal sample size for DA is not mentioned in the provided information.