A 1-V 450-nW Fully Integrated Programmable Biomedical Sensor Interface Chip

TLDR
The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter that achieves low signal distortion and high dynamic range under low voltage operations.
Abstract
This paper presents a fully integrated programmable biomedical sensor interface chip dedicated to the processing of various types of biomedical signals. The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter. A novel balanced tunable pseudo-resistor is proposed to achieve low signal distortion and high dynamic range under low voltage operations. A 53 nW, 30 kHz relaxation oscillator is included on-chip for low power consumption and full integration. The design was fabricated in a 0.35 μm standard CMOS process and tested at 1 V supply. The analog front-end has measured frequency response from 4.5 mHz to 292 Hz, programmable gains from 45.6 dB to 60 dB, input referred noise of 2.5 μV rms in the amplifier bandwidth, a noise efficiency factor (NEF) of 3.26, and a low distortion of less than 0.6% with full voltage swing at the ADC input. The system consumes 445 nA in the 31 Hz narrowband mode for heart rate detection and 895 nA in the 292 Hz wideband mode for ECG recording.

read more

Content maybe subject to copyright    Report

Citations
More filters
Proceedings ArticleDOI

Architecture exploration for ambient energy harvesting nonvolatile processors

TL;DR: The simulation platform in this paper is calibrated using measured results from a fabricated nonvolatile processor and used to explore the design space for a nonVolatile processor with different architectures, different input power sources, and policies for maximizing forward progress.
Journal ArticleDOI

A 53-nW 9.1-ENOB 1-kS/s SAR ADC in 0.13- $\mu$ m CMOS for Medical Implant Devices

TL;DR: An ultra-low power SAR ADC for medical implant devices is described, imposing maximum simplicity on the ADC architecture, low transistor count and matched capacitive DAC with a switching scheme which results in full-range sampling without switch bootstrapping and extra reset voltage.
Journal ArticleDOI

A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring

TL;DR: In this paper, an active electrode system for gel-free biopotential EEG signal acquisition is presented, which consists of front-end chopper amplifiers and a back-end common-mode feedback (CMFB) circuit.
Proceedings ArticleDOI

A 160μW 8-channel active electrode system for EEG monitoring

TL;DR: To reduce the total power dissipation, this paper proposes a biopotential monitoring system based on active electrodes with gain, which would require a power-hungry back-end to keep the total integrated noise at acceptable levels.
Journal ArticleDOI

A Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection

TL;DR: This paper describes a micropower low-noise neural front-end circuit capable of recording epileptic fast ripples (FR) and is the first to achieve the FR-recording functionality.