scispace - formally typeset
Journal ArticleDOI

Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study

K G Boone, +1 more
- 01 Sep 1996 - 
- Vol. 34, Iss: 5, pp 351-353
Reads0
Chats0
TLDR
It is concluded that the patient's skin should be abraded to reduce impedance, and measurements should be avoided in the first 10 min after electrode placement, to allow satisfactory images.
Abstract
A computer simulation is used to investigate the relationship between skin impedance and image artefacts in electrical impedance tomography. Sets of electrode impedance are generated with a pseudo-random distribution and used to introduce errors in boundary voltage measurements. To simplify the analysis, the non-idealities in the current injection circuit are replaced by a fixed common-mode error term. The boundary voltages are reconstructed into images and inspected. Where the simulated skin impedance remains constant between measurements, large impedances (> 2k omega) do not cause significant degradation of the image. Where the skin impedances 'drift' between measurements, a drift of 5% from a starting impedance of 100 omega is sufficient to cause significant image distortion. If the skin impedances vary randomly between measurements, they have to be less than 10 omega to allow satisfactory images. Skin impedances are typically 100-200 omega at 50 kHz on unprepared skin. These values are sufficient to cause image distortion if they drift over time. It is concluded that the patient's skin should be abraded to reduce impedance, and measurements should be avoided in the first 10 min after electrode placement.

read more

Citations
More filters
Journal ArticleDOI

Computationally Efficient Time-Recursive IAA-Based Blood Velocity Estimation

TL;DR: By exploiting the rich structure of the iterative adaptive approach (IAA) based estimator, this work examines how these estimates can be efficiently implemented in a time-recursive manner using both exact and approximate formulations of the method.
Journal ArticleDOI

F – k Domain Imaging for Synthetic Aperture Sequential Beamforming

TL;DR: The concept of two-stage beamforming based on virtual source-receivers is exploited, which reduces the front-end computational load while maintaining a similar data rate and frame rate compared to dynamic-receive beamforming.
Journal ArticleDOI

Robust Phase Velocity Dispersion Estimation of Viscoelastic Materials Used for Medical Applications Based on the Multiple Signal Classification Method

TL;DR: An alternative method to the classical 2-D Fourier transform (2D-FT) that uses the multiple signal classification (MUSIC) technique to provide robust estimation of the shear wave velocity and phase velocity dispersion curves in viscoelastic media is presented.
Journal ArticleDOI

Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning

TL;DR: The proposed method reconstructs the Doppler signal segment by segment using a block sparse Bayesian learning (BSBL) algorithm based CS reconstruction, linked to the unique ability of BSBL to exploit block-correlated signals and to recover non-sparse signals.
Journal ArticleDOI

Joint Subarray Coherence and Minimum Variance Beamformer for Multitransmission Ultrasound Imaging Modalities

TL;DR: A novel beamformer for better imaging quality in multitransmission ultrasound modalities that can preserve the high resolution of MV and the high contrast of CF and has high robustness against the channel noise and sound velocity errors.
References
More filters
Journal ArticleDOI

The Sheffield data collection system.

TL;DR: Any improvement in spatial resolution can only be made at the expense of speed and sensitivity which may well be the more important factors in determining the clinical utility of APT.
Journal ArticleDOI

Using compound electrodes in electrical impedance tomography

TL;DR: A sensitivity study showed that the reconstructed resistivity distributions are less dependent on the unknown contact resistance values for a compound electrode than a conventional electrode and that the use of a compound electrodes results in improved images for the reconstruction algorithm.
Journal ArticleDOI

Finite element method and reconstruction algorithms in electrical impedance tomography

TL;DR: To validate the method of data analysis, a theoretical model was developed, with the limiting case being the turn-on transient for a membrane covered spherical cathode, and the results agree with previously published data.

Assessment of noise and drift artefacts in electrical impedance tomography measurements using the sheffield Mark I system

K. G. Boone, +1 more
TL;DR: In this article, the mesures peuvent etre affectees d'artefacts dus au bruit et aux derives are discussed, e.g., les variations de l'impedance du fluide and celles des impedances d'electrode sont peu importantes.
Related Papers (5)