Multi‐system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice‐water phantom

Reads0
Chats0
TLDR
To determine quantitative quality control procedures to evaluate technical variability in multi‐center measurements of the diffusion coefficient of water as a prerequisite to use of the biomarker apparent diffusion coefficient (ADC) in multi-center clinical trials.
Abstract
To determine quantitative quality control procedures to evaluate technical variability in multi-center measurements of the diffusion coefficient of water as a prerequisite to use of the biomarker apparent diffusion coefficient (ADC) in multi-center clinical trials.A uniform data acquisition protocol was developed and shared with 18 participating test sites along with a temperature-controlled diffusion phantom delivered to each site. Usable diffusion weighted imaging data of ice water at five b-values were collected on 35 clinical MRI systems from three vendors at two field strengths (1.5 and 3 Tesla [T]) and analyzed at a central processing site.Standard deviation of bore-center ADCs measured across 35 scanners was 10%) vendor-specific and system-specific spatial nonuniformity ADC bias was detected for the off-center measurement that was consistent with gradient nonlinearity.Standardization of DWI protocol has improved reproducibility of ADC measurements and allowed identifying spatial ADC nonuniformity as a source of error in multi-site clinical studies.

read more

Citations
More filters
Journal ArticleDOI

Repeatability of Multiparametric Prostate MRI Radiomics Features.

TL;DR: In this article, the authors assessed the repeatability of radiomics features on small prostate tumors using test-retest multiparametric Magnetic Resonance Imaging (mpMRI) and found that the feature's value must remain stable between two scans, if the conditions remain stable.
References
More filters
Journal ArticleDOI

Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations

TL;DR: DW-MRI should be tested as an imaging biomarker in the context of well-defined clinical trials, by adding DW-MRI to existing NCI-sponsored trials, particularly those with tissue sampling or survival indicators, and standards for measurement, analysis, and display are needed.
Journal ArticleDOI

Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements

TL;DR: In this paper, the authors present reference data as a function of temperature for 1H PFG NMR in the temperature range from + 5 to + 55°C and added literature data obtained from tracer methods in the range between 0 and + 100°C.
Journal ArticleDOI

Pressure and temperature dependence of self-diffusion in water

TL;DR: The self-diffusion coefficient for pure liquid water has been measured at temperatures between 275.2 and 498.2 K and at pressures up to 1.75 kbar by the proton spin echo method as discussed by the authors.
Journal ArticleDOI

Diffusion and nuclear spin relaxation in water

TL;DR: In this paper, the diffusion coefficient and the spin lattice relaxation time of protons in ordinary water have been measured in the temperature range 0-100\ifmmode^\circ\else\textdegree\fi{}C using nuclear magnetic resonance free precession techniques.
Related Papers (5)