scispace - formally typeset
Open AccessJournal ArticleDOI

Rapid Diffusion of Green Fluorescent Protein in the Mitochondrial Matrix

TLDR
The rapid and unrestricted diffusion of solutes in the mitochondrial matrix suggests that metabolite channeling may not be required to overcome diffusive barriers, and it is proposed that the clustering of matrix enzymes in membrane-associated complexes might serve to establish a relatively uncrowded aqueous space in which solutes can freely diffuse.
Abstract
It is thought that the high protein density in the mitochondrial matrix results in severely restricted solute diffusion and metabolite channeling from one enzyme to another without free aqueous-phase diffusion. To test this hypothesis, we measured the diffusion of green fluorescent protein (GFP) expressed in the mitochondrial matrix of fibroblast, liver, skeletal muscle, and epithelial cell lines. Spot photobleaching of GFP with a 100x objective (0.8-micron spot diam) gave half-times for fluorescence recovery of 15-19 ms with >90% of the GFP mobile. As predicted for aqueous-phase diffusion in a confined compartment, fluorescence recovery was slowed or abolished by increased laser spot size or bleach time, and by paraformaldehyde fixation. Quantitative analysis of bleach data using a mathematical model of matrix diffusion gave GFP diffusion coefficients of 2-3 x 10(-7) cm2/s, only three to fourfold less than that for GFP diffusion in water. In contrast, little recovery was found for bleaching of GFP in fusion with subunits of the fatty acid beta-oxidation multienzyme complex that are normally present in the matrix. Measurement of the rotation of unconjugated GFP by time-resolved anisotropy gave a rotational correlation time of 23.3 +/- 1 ns, similar to that of 20 ns for GFP rotation in water. A rapid rotational correlation time of 325 ps was also found for a small fluorescent probe (BCECF, approximately 0.5 kD) in the matrix of isolated liver mitochondria. The rapid and unrestricted diffusion of solutes in the mitochondrial matrix suggests that metabolite channeling may not be required to overcome diffusive barriers. We propose that the clustering of matrix enzymes in membrane-associated complexes might serve to establish a relatively uncrowded aqueous space in which solutes can freely diffuse.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Studying protein dynamics in living cells.

TL;DR: Live cell imaging, in combination with photobleaching, energy transfer or fluorescence correlation spectroscopy are providing unprecedented insights into the movement of proteins and their interactions with cellular components.
Journal ArticleDOI

Development and use of fluorescent protein markers in living cells.

TL;DR: The development of highly visible and minimally perturbing fluorescent proteins that, together with updated fluorescent imaging techniques, are providing unprecedented insights into the movement of proteins and their interactions with cellular components in living cells are traced.
Journal ArticleDOI

Macromolecular crowding: an important but neglected aspect of the intracellular environment.

TL;DR: It is proposed that the addition of crowding agents should become as routine as controlling pH and ionic strength if the authors are to meet the objective of studying biological molecules under more physiologically relevant conditions.
Journal ArticleDOI

Size-dependent DNA Mobility in Cytoplasm and Nucleus

TL;DR: The results suggest that the highly restricted diffusion of DNA fragments in nucleoplasm results from extensive binding to immobile obstacles and that the decreased lateral mobility of DNAs >250 bp in cytoplasm is because of molecular crowding.
Journal ArticleDOI

Green fluorescent protein as a noninvasive intracellular pH indicator.

TL;DR: The results establish the application of GFP as a targetable, noninvasive indicator of intracellular pH and suggest that GFP pH sensitivity involves simple protonation events at a pH of >5, but both protonations and conformational changes at lower pH.
References
More filters
Journal ArticleDOI

Construction and evaluation of a frequency-domain epifluorescence microscope for lifetime and anisotropy decay measurements in subcellular domains.

TL;DR: L Lifetime and anisotropy decay measured by microscopy agreed with data obtained by cuvette fluorimetry (0.5 micron laser spot) and new biological applications for time-resolved fluorescence microscopy are discussed.
Journal ArticleDOI

Construction and performance of a photobleaching recovery apparatus with microsecond time resolution

TL;DR: An apparatus constructed to measure sub-millisecond fluorescence recovery processes in living cells and was coupled to an inverted microscope for measurement of fluorescence by epi-illumination or total internal reflection, evaluated by measurement of the rapid fluorescence recoveries of fluorescein and fluorscein-dextrans in solutions and living cells.
Journal ArticleDOI

The effect of viscosity on the apparent decomposition rate on enzyme--ligand complexes.

TL;DR: A theoretical model is presented for describing a previously untreated effect of viscosity on the apparent decomposition rate of enzyme-ligand complexes and serves as a tool to obtain new information about the energetic processes of enzyme action.
Related Papers (5)