scispace - formally typeset
Search or ask a question

Showing papers in "arXiv: Instrumentation and Detectors in 2015"


Journal ArticleDOI
Fengpeng An1, Guangpeng An, Qi An2, Vito Antonelli3  +226 moreInstitutions (55)
TL;DR: The Jiangmen Underground Neutrino Observatory (JUNO) as mentioned in this paper is a 20 kton multi-purpose underground liquid scintillator detector with the determination of the neutrino mass hierarchy as a primary physics goal.
Abstract: The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose underground liquid scintillator detector, was proposed with the determination of the neutrino mass hierarchy as a primary physics goal. It is also capable of observing neutrinos from terrestrial and extra-terrestrial sources, including supernova burst neutrinos, diffuse supernova neutrino background, geoneutrinos, atmospheric neutrinos, solar neutrinos, as well as exotic searches such as nucleon decays, dark matter, sterile neutrinos, etc. We present the physics motivations and the anticipated performance of the JUNO detector for various proposed measurements. By detecting reactor antineutrinos from two power plants at 53-km distance, JUNO will determine the neutrino mass hierarchy at a 3-4 sigma significance with six years of running. The measurement of antineutrino spectrum will also lead to the precise determination of three out of the six oscillation parameters to an accuracy of better than 1\%. Neutrino burst from a typical core-collapse supernova at 10 kpc would lead to ~5000 inverse-beta-decay events and ~2000 all-flavor neutrino-proton elastic scattering events in JUNO. Detection of DSNB would provide valuable information on the cosmic star-formation rate and the average core-collapsed neutrino energy spectrum. Geo-neutrinos can be detected in JUNO with a rate of ~400 events per year, significantly improving the statistics of existing geoneutrino samples. The JUNO detector is sensitive to several exotic searches, e.g. proton decay via the $p\to K^++\bar u$ decay channel. The JUNO detector will provide a unique facility to address many outstanding crucial questions in particle and astrophysics. It holds the great potential for further advancing our quest to understanding the fundamental properties of neutrinos, one of the building blocks of our Universe.

622 citations


Journal Article
TL;DR: In this paper, the physics program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neurtrino Facility (LBNF) is described.
Abstract: The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described.

422 citations


Posted Content
TL;DR: A new general purpose fixed target facility is proposed at the CERN SPS accelerator which is aimed at exploring the domain of hidden particles and making measurements with tau neutrinos as discussed by the authors.
Abstract: A new general purpose fixed target facility is proposed at the CERN SPS accelerator which is aimed at exploring the domain of hidden particles and make measurements with tau neutrinos. Hidden particles are predicted by a large number of models beyond the Standard Model. The high intensity of the SPS 400~GeV beam allows probing a wide variety of models containing light long-lived exotic particles with masses below ${\cal O}$(10)~GeV/c$^2$, including very weakly interacting low-energy SUSY states. The experimental programme of the proposed facility is capable of being extended in the future, e.g. to include direct searches for Dark Matter and Lepton Flavour Violation.

360 citations


Journal ArticleDOI
TL;DR: In this paper, the status of direct dark matter searches is summarized, focusing on the detector technologies used to directly detect a dark matter particle producing recoil energies in the keV energy scale.
Abstract: In the past decades, several detector technologies have been developed with the quest to directly detect dark matter interactions and to test one of the most important unsolved questions in modern physics. The sensitivity of these experiments has improved with a tremendous speed due to a constant development of the detectors and analysis methods, proving uniquely suited devices to solve the dark matter puzzle, as all other discovery strategies can only indirectly infer its existence. Despite the overwhelming evidence for dark matter from cosmological indications at small and large scales, a clear evidence for a particle explaining these observations remains absent. This review summarises the status of direct dark matter searches, focussing on the detector technologies used to directly detect a dark matter particle producing recoil energies in the keV energy scale. The phenomenological signal expectations, main background sources, statistical treatment of data and calibration strategies are discussed.

270 citations


Journal ArticleDOI
Elena Aprile, Jelle Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, Lior Arazi, F. Arneodo, C. Balan, P. Barrow, Laura Baudis, Boris Bauermeister, T. Berger, P. A. Breur, Amos Breskin, April S. Brown, Ethan Brown, S. Bruenner, Giacomo Bruno, Ran Budnik, L. Bütikofer, João Cardoso, M. Cervantes, D. Cichon, D. Coderre, Auke-Pieter Colijn, Jan Conrad, H. Contreras, Jean-Pierre Cussonneau, M. P. Decowski, P. de Perio, P. Di Gangi, A. Di Giovanni, E. Duchovni, S. Fattori, A. D. Ferella, A. Fieguth, D. Franco, W. Fulgione, Michelle Galloway, M. Garbini, C. Geis, Luke Goetzke, Z. Greene, C. Grignon, E. K. U. Gross, W. Hampel, C. Hasterok, R. Itay, Florian Kaether, B. Kaminsky, G. Kessler, A. Kish, H. Landsman, R. F. Lang, D. Lellouch, L. Levinson, M. Le Calloch, C. Levy, Sebastian Lindemann, Manfred Lindner, J. A. M. Lopes, A. Lyashenko, S. Macmullin, A. Manfredini, T. Marrodán Undagoitia, Julien Masbou, F. V. Massoli, D. Mayani, A. J. Melgarejo Fernandez, Y. Meng, M. Messina, K. Micheneau, B. Miguez, A. Molinario, M. Murra, J. Naganoma, Uwe Oberlack, S. E. A. Orrigo, P. Pakarha, Bart Pelssers, R. Persiani, F. Piastra, J. Pienaar, Guillaume Plante, N. Priel, L. Rauch, S. Reichard, C. Reuter, A. Rizzo, S. Rosendahl, N. Rupp, J.M.F. dos Santos, Gabriella Sartorelli, M. Scheibelhut, S. Schindler, Jochen Schreiner, Marc Schumann, L. Scotto Lavina, M. Selvi, P. Shagin, Hardy Simgen, A. Stein, D. Thers, A. Tiseni, G. C. Trinchero, C. Tunnell, M. von Sivers, R. Wall, Hulin Wang, Max Weber, Yuehuan Wei, Ch. Weinheimer, J. Wulf, Yanxi Zhang 
TL;DR: In this paper, the expected sensitivity of the XENON1T experiment to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds, was studied.
Abstract: The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.

267 citations


ReportDOI
D. S. Akerib1, D. S. Akerib2, R. M. Preece, V. Bugaev  +191 moreInstitutions (2)
TL;DR: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report as mentioned in this paper. And the LZ detector will be located at the Sanford Underground Research Facility in South Dakota.
Abstract: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.

212 citations


ReportDOI
TL;DR: The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS as mentioned in this paper.
Abstract: The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval

177 citations


Posted Content
TL;DR: In this article, a Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors located along the Booster NN (BNB) at Fermilab is presented.
Abstract: A Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab is presented. This new SBN Program will deliver a rich and compelling physics opportunity, including the ability to resolve a class of experimental anomalies in neutrino physics and to perform the most sensitive search to date for sterile neutrinos at the eV mass-scale through both appearance and disappearance oscillation channels. Using data sets of 6.6e20 protons on target (P.O.T.) in the LAr1-ND and ICARUS T600 detectors plus 13.2e20 P.O.T. in the MicroBooNE detector, we estimate that a search for muon neutrino to electron neutrino appearance can be performed with ~5 sigma sensitivity for the LSND allowed (99% C.L.) parameter region. In this proposal for the SBN Program, we describe the physics analysis, the conceptual design of the LAr1-ND detector, the design and refurbishment of the T600 detector, the necessary infrastructure required to execute the program, and a possible reconfiguration of the BNB target and horn system to improve its performance for oscillation searches.

176 citations


Journal ArticleDOI
S. Andringa, E. Arushanova1, S. Asahi2, M. Askins3, D. J. Auty4, A. Back1, A. Back5, Z. Barnard6, N. Barros7, E. W. Beier7, A. Bialek4, S. D. Biller8, E. Blucher9, R. Bonventre7, D. Braid6, E. Caden6, E. J. Callaghan7, J. Caravaca10, J. Caravaca11, João Carvalho12, L. Cavalli8, D. Chauhan6, D. Chauhan2, M. L. Chen2, O. Chkvorets6, Karl J. Clark2, Karl J. Clark8, Karl J. Clark5, B. T. Cleveland6, I. T. Coulter8, I. T. Coulter7, D. Cressy6, X. Dai2, C. Darrach6, B. Davis-Purcell13, Rehan Deen8, Rehan Deen7, M. M. Depatie6, F.B. Descamps11, F.B. Descamps10, F. Di Lodovico1, N. Duhaime6, F. Duncan6, J. Dunger8, E. Falk5, N. Fatemighomi2, R. Ford6, P. Gorel4, C. Grant3, S. Grullon7, E. Guillian2, A. L. Hallin4, D. Hallman6, S. Hans14, J. Hartnell5, P. J. Harvey2, M. Hedayatipour4, W. J. Heintzelman7, R. L. Helmer13, B. Hreljac6, J. Hu4, T. Iida2, C. M. Jackson10, C. M. Jackson11, N. A. Jelley8, C. J. Jillings6, C. Jones8, P. G. Jones8, P. G. Jones1, K. Kamdin10, K. Kamdin11, T. Kaptanoglu7, J. Kaspar15, Paul Keener7, P. Khaghani6, L. Kippenbrock15, J. R. Klein7, R. Knapik16, R. Knapik7, J. Kofron15, L. L. Kormos17, S. Korte6, C. Kraus6, C. B. Krauss4, K. Labe9, I. Lam2, C. Lan2, B. J. Land10, B. J. Land11, S. Langrock1, A. LaTorre9, I. Lawson6, G. Lefeuvre5, E. J. Leming5, J. Lidgard8, X. Liu2, Y. Liu2, V. Lozza18, S. Maguire14, A. Maio19, K. Majumdar8, S. Manecki2, J. Maneira19, E. Marzec7, A. Mastbaum7, N. McCauley20, A. B. McDonald2, J. E. McMillan21, P. Mekarski4, C. Miller2, Yuvraj Mohan7 
TL;DR: SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada as discussed by the authors, whose primary goal is a search for the neutrinoless double-beta decay (0$ u\beta\beta$) of 130Te.
Abstract: SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta decay (0$ u\beta\beta$) of 130Te. In Phase I, the detector will be loaded with 0.3% natural tellurium, corresponding to nearly 800 kg of 130Te, with an expected effective Majorana neutrino mass sensitivity in the region of 55-133 meV, just above the inverted mass hierarchy. Recently, the possibility of deploying up to ten times more natural tellurium has been investigated, which would enable SNO+ to achieve sensitivity deep into the parameter space for the inverted neutrino mass hierarchy in the future. Additionally, SNO+ aims to measure reactor antineutrino oscillations, low-energy solar neutrinos, and geoneutrinos, to be sensitive to supernova neutrinos, and to search for exotic physics. A first phase with the detector filled with water will begin soon, with the scintillator phase expected to start after a few months of water data taking. The 0$ u\beta\beta$ Phase I is foreseen for 2017.

171 citations


Journal ArticleDOI
TL;DR: In this article, the authors discuss the scope of such research in the backdrop of the IndIGO action plan and the LIGO-India project, and discuss the potential for substantial contributions to global GW research and astronomy.
Abstract: Initiatives by the IndIGO (Indian Initiative in Gravitational Wave Observations) Consortium during the past three years have materialized into concrete plans and project opportunities for instrumentation and research based on advanced interferometer detectors . With the LIGO-India opportunity, this initiative has a taken a promising path towards significant participation in gravitational wave (GW) astronomy and research, and in developing and nurturing precision fabrication and measurement technologies in India. The proposed LIGO-India detector will foster integrated development of frontier GW research in India and will provide opportunity for substantial contributions to global GW research and astronomy. Widespread interest and enthusiasm about these developments in premier research and educational institutions in India lead to the expectation that there will be a grand surge of activity in precision metrology, instrumentation, data handling and computation etc. in the context of LIGO-India. I discuss the scope of such research in the backdrop of the IndIGO action plan and the LIGO-India project.

160 citations


Posted Content
TL;DR: The Jiangmen Underground Neutrino Observatory (JUNO) as discussed by the authors was proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector.
Abstract: Author(s): Adam, T; An, F; An, G; An, Q; Anfimov, N; Antonelli, V; Baccolo, G; Baldoncini, M; Baussan, E; Bellato, M; Bezrukov, L; Bick, D; Blyth, S; Boarin, S; Brigatti, A; Brugiere, T; Brugnera, R; Avanzini, MB; Busto, J; Cabrera, A; Cai, H; Cai, X; Cammi, A; Cao, D; Cao, G; Cao, J; Chang, J; Chang, Y; Chen, M; Chen, P; Chen, Q; Chen, S; Chen, S; Chen, S; Chen, X; Chen, Y; Cheng, Y; Chiesa, D; Chukanov, A; Clemenza, M; Clerbaux, B; D'Angelo, D; Kerret, HD; Deng, Z; Deng, Z; Ding, X; Ding, Y; Djurcic, Z; Dmitrievsky, S; Dolgareva, M; Dornic, D; Doroshkevich, E; Dracos, M; Drapier, O; Dusini, S; Diaz, MA; Enqvist, T; Fan, D; Fang, C; Fang, J; Fang, X; Favart, L; Fedoseev, D; Fiorentini, G; Ford, R; Formozov, A; Gaigher, R; Gan, H; Garfagnini, A; Gaudiot, G; Genster, C; Giammarchi, M; Giuliani, F; Gonchar, M; Gong, G; Gong, H; Gonin, M; Gornushkin, Y; Grassi, M; Grewing, C; Gromov, V; Gu, M; Guan, M; Guarino, V; Guo, W | Abstract: The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$\sigma$, and determine neutrino oscillation parameters $\sin^2\theta_{12}$, $\Delta m^2_{21}$, and $|\Delta m^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.

Journal ArticleDOI
TL;DR: In this paper, the authors presented the physics potential of the ICAL detector as obtained from realistic detector simulations and gave the expected physics reach of the detector with 10 years of runtime.
Abstract: The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the multi-GeV range. This study will be crucial to address some of the outstanding issues in neutrino oscillation physics, including the fundamental issue of neutrino mass hierarchy. In this document, we present the physics potential of the detector as obtained from realistic detector simulations. We describe the simulation framework, the neutrino interactions in the detector, and the expected response of the detector to particles traversing it. The ICAL detector can determine the energy and direction of the muons to a high precision, and in addition, its sensitivity to multi-GeV hadrons increases its physics reach substantially. Its charge identification capability, and hence its ability to distinguish neutrinos from antineutrinos, makes it an efficient detector for determining the neutrino mass hierarchy. In this report, we outline the analyses carried out for the determination of neutrino mass hierarchy and precision measurements of atmospheric neutrino mixing parameters at ICAL, and give the expected physics reach of the detector with 10 years of runtime. We also explore the potential of ICAL for probing new physics scenarios like CPT violation and the presence of magnetic monopoles.

Journal ArticleDOI
TL;DR: In this paper, the Avogadro constant was determined by counting the atoms in an isotopically enriched silicon crystal, which achieved the target relative standard uncertainty of $2.0 \times 10^{-8}$ necessary for the realization of the new kilogram.
Abstract: New results are reported from an ongoing international research effort to accurately determine the Avogadro constant by counting the atoms in an isotopically enriched silicon crystal. The surfaces of two 28Si-enriched spheres were decontaminated and reworked in order to produce an outer surface without metal contamination and improved sphericity. New measurements were then made on these two reconditioned spheres using improved methods and apparatuses. When combined with other recently refined parameter measurements, the Avogadro constant derived from these new results has a value of $N_A = 6.022 140 76(12) \times 10^{23}$ mol$^{-1}$. The X-ray crystal density method has thus achieved the target relative standard uncertainty of $2.0 \times 10^{-8}$ necessary for the realization of the definition of the new kilogram.

Journal ArticleDOI
TL;DR: In this paper, the authors present the seismic isolation instrumentation and strategy developed for Advanced LIGO interferometers and present the performance recently achieved with the Advanced LigO observatory.
Abstract: Isolating ground-based interferometric gravitational wave observatories from environmental disturbances is one of the great challenges of the advanced detector era. In order to directly observe gravitational waves, the detector components and test masses must be highly inertially decoupled from the ground motion not only to sense the faint strain of space-time induced by gravitational waves, but also to maintain the resonance of the very sensitive 4 km interferometers. This article presents the seismic isolation instrumentation and strategy developed for Advanced LIGO interferometers. It reviews over a decade of research on active isolation in the context of gravitational wave detection, and presents the performance recently achieved with the Advanced LIGO observatory. Lastly, it discusses prospects for future developments in active seismic isolation and the anticipated benefits to astrophysical gravitational wave searches. Beyond gravitational wave research, the goal of this article is to provide detailed isolation strategy guidelines for sensitive ground-based physics experiments that may benefit from similar levels of inertial isolation.

Journal ArticleDOI
TL;DR: NEXT-100 as discussed by the authors is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($β \beta 0 u$) decay of Xe-136.
Abstract: NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($\beta \beta 0 u$) decay of Xe-136. The detector possesses two features of great value for $\beta \beta 0 u$ searches: energy resolution better than 1\% FWHM at the $Q$ value of Xe-136 and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most $4\times10^{-4}$ counts keV$^{-1}$ kg$^{-1}$ yr$^{-1}$. Accordingly, the detector will reach a sensitivity to the \bbonu-decay half-life of $2.8\times10^{25}$ years (90\% CL) for an exposure of 100 $\mathrm{kg}\cdot\mathrm{year}$, or $6.0\times10^{25}$ years after a run of 3 effective years.

Journal ArticleDOI
TL;DR: The Precision Reactor Oscillation and Spectrum Experiment (PROSPECT) as discussed by the authors was designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances.
Abstract: The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT Phase I consists of a movable 3-ton antineutrino detector at distances of 7 - 12 m from the reactor core. It will probe the best-fit point of the $ u_e$ disappearance experiments at 4$\sigma$ in 1 year and the favored region of the sterile neutrino parameter space at $>$3$\sigma$ in 3 years. With a second antineutrino detector at 15 - 19 m from the reactor, Phase II of PROSPECT can probe the entire allowed parameter space below 10 eV$^{2}$ at 5$\sigma$ in 3 additional years. The measurement of the reactor antineutrino spectrum and the search for short-baseline oscillations with PROSPECT will test the origin of the spectral deviations observed in recent $\theta_{13}$ experiments, search for sterile neutrinos, and conclusively address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly.

Posted Content
TL;DR: In this paper, the authors analyzed the difficulties of actually building an atomic resolution interaction-free electron microscope, or "quantum electron microscope", which would require a number of unique components not found in conventional transmission electron microscopes, such as coherent electron-beam splitter or two-state-coupler, and a resonator structure to allow each electron to interrogate the specimen multiple times, thus supporting high success probabilities for interactionfree detection of the specimen.
Abstract: One of the astounding consequences of quantum mechanics is that it allows the detection of a target using an incident probe, with only a low probability of interaction of the probe and the target. This 'quantum weirdness' could be applied in the field of electron microscopy to generate images of beam-sensitive specimens with substantially reduced damage to the specimen. A reduction of beam-induced damage to specimens is especially of great importance if it can enable imaging of biological specimens with atomic resolution. Following a recent suggestion that interaction-free measurements are possible with electrons, we now analyze the difficulties of actually building an atomic resolution interaction-free electron microscope, or "quantum electron microscope". A quantum electron microscope would require a number of unique components not found in conventional transmission electron microscopes. These components include a coherent electron-beam splitter or two-state-coupler, and a resonator structure to allow each electron to interrogate the specimen multiple times, thus supporting high success probabilities for interaction-free detection of the specimen. Different system designs are presented here, which are based on four different choices of two-state-couplers: a thin crystal, a grating mirror, a standing light wave and an electro-dynamical pseudopotential. Challenges for the detailed electron optical design are identified as future directions for development. While it is concluded that it should be possible to build an atomic resolution quantum electron microscope, we have also identified a number of hurdles to the development of such a microscope and further theoretical investigations that will be required to enable a complete interpretation of the images produced by such a microscope.

Posted Content
L. Agostino1, B. Andrieu1, R. Asfandiyarov2, D. Autiero3, O. Bésida, F. Bay4, R. Bayes5, A.M. Blebea-Apostu, A. Blondel2, M. Bogomilov6, S. Bolognesi, S. Bordoni, A. Bravar2, M. Buizza-Avanzini1, Franck Cadoux2, D. Caiulo3, M. Calin7, Mario Campanelli8, C. Cantini4, L. Chaussard3, D. Chesneanu, N. Colino, Paolo Crivelli4, I. De Bonis9, Y. Déclais3, J.V. Dawson1, C. de la Taille10, P. Del Amo Sanchez9, A. Delbart, S. Di Luise4, D. Duchesneau9, F. Dulucq10, J. Dumarchez1, Ilias Efthymiopoulos11, S. Emery, Timo Enqvist12, L. Epprecht4, T. Esanu7, D. Franco1, M. Friend, V. Galymov, A. Gendotti4, C. Giganti1, I. Gil-Botella, M.C. Gomoiu, P. Gorodetzky1, A. Haesler2, T. Hasegawa, S. Horikawa4, M. Ieva, Alexandru Jipa7, Y. Karadzhov2, I. Karpikov13, A. N. Khotjantsev13, A. Korzenev2, D. Kryn1, Yu.A. Kudenko13, Pasi Kuusiniemi12, Ionel Lazanu7, J.-M. Lévy1, Kai Loo14, Thorsten Lux, Jukka Maalampi14, Romul Margineanu, J. Marteau3, C. Martin2, G. Martin-Chassard10, E. Mazzucato, A. Mefodiev13, Oleg Mineev13, B. Mitrica, S. Murphy4, T. Nakadaira, Marzio Nessi11, K. Nikolics4, L. Nita7, Etam Noah2, P. Novella, G. Nuijten, T. Ovsiannikova13, C. Palomares, T. Patzak1, E. Pennacchio3, L. Periale4, H. Pessard9, B. A. Popov1, M. Ravonel2, M. A. M. Rayner2, C. Regenfus4, C. Ristea7, Oana Ristea7, Arnaud Robert1, André Rubbia4, K. Sakashita, F. Sanchez, R. Santorelli, E. Scantamburlo2, F. Sergiampietri, D. Sgalaberna4, Maciej Slupecki14, F. J. P. Soler5, D. Stanca, A. Tonazzo1, Wladyslaw Henryk Trzaska14, R. Tsenov6, G. Vankova-Kirilova6, F. Vannucci1, G. Vasseur, A. Verdugo, T. Viant4, S. Wu4, N. Yershov13, L. Zambelli, M. Zito 
TL;DR: The DLAr detector as mentioned in this paper is an industrial prototype of the design discussed in the EoI and scalable to 20 kton or 50 kton with test beam access at CERN North Area (NA).
Abstract: In June 2012, an Expression of Interest for a long-baseline experiment (LBNO) has been submitted to the CERN SPSC. LBNO considers three types of neutrino detector technologies: a double-phase liquid argon (LAr) TPC and a magnetised iron detector as far detectors. For the near detector, a high-pressure gas TPC embedded in a calorimeter and a magnet is the baseline design. A mandatory milestone is a concrete prototyping effort towards the envisioned large-scale detectors, and an accompanying campaign of measurements aimed at assessing the detector associated systematic errors. The proposed $6\times 6\times 6$m$^3$ DLAr is an industrial prototype of the design discussed in the EoI and scalable to 20 kton or 50~kton. It is to be constructed and operated in a controlled laboratory and surface environment with test beam access, such as the CERN North Area (NA). Its successful operation and full characterisation will be a fundamental milestone, likely opening the path to an underground deployment of larger detectors. The response of the DLAr demonstrator will be measured and understood with an unprecedented precision in a charged particle test beam (0.5-20 GeV/c). The exposure will certify the assumptions and calibrate the response of the detector, and allow to develop and to benchmark sophisticated reconstruction algorithms, such as those of 3-dimensional tracking, particle ID and energy flow in liquid argon. All these steps are fundamental for validating the correctness of the physics performance described in the LBNO EoI.

Journal ArticleDOI
TL;DR: The German–British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001 and sensitivity improvements of up to a factor of four at the high-frequency end of the observation band have been achieved.
Abstract: The German-British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001. After GEO 600 participated in science runs with other first-generation detectors, a program known as GEO-HF began in 2009. The goal was to improve the detector sensitivity at high frequencies, around 1 kHz and above, with technologically advanced yet minimally invasive upgrades. Simultaneously, the detector would record science quality data in between commissioning activities. As of early 2014, all of the planned upgrades have been carried out and sensitivity improvements of up to a factor of four at the high-frequency end of the observation band have been achieved. Besides science data collection, an experimental program is ongoing with the goal to further improve the sensitivity and evaluate future detector technologies. We summarize the results of the GEO-HF program to date and discuss its successes and challenges.

Journal ArticleDOI
TL;DR: In this paper, the sensitivity of DARWIN to spin independent and spin dependent WIMP-nucleon scattering interactions was investigated. But the sensitivity was not considered in this paper, since it was assumed that neutrinos will scatter coherently off the xenon nuclei.
Abstract: We study the sensitivity of multi ton-scale time projection chambers using a liquid xenon target, e.g., the proposed DARWIN instrument, to spin-independent and spin-dependent WIMP-nucleon scattering interactions. Taking into account realistic backgrounds from the detector itself as well as from neutrinos, we examine the impact of exposure, energy threshold, background rejection efficiency and energy resolution on the dark matter sensitivity. With an exposure of 200 t x y and assuming detector parameters which have been already demonstrated experimentally, spin-independent cross sections as low as $2.5 \times 10^{-49}$ cm$^2$ can be probed for WIMP masses around 40 GeV/$c^2$. Additional improvements in terms of background rejection and exposure will further increase the sensitivity, while the ultimate WIMP science reach will be limited by neutrinos scattering coherently off the xenon nuclei.

Journal ArticleDOI
TL;DR: The operation of a cryogenic instrumentation platform incorporating commercially available field-programmable gate arrays (FPGAs) enables signal routing, multiplexing, and complex digital signal processing in close proximity to cooled devices or detectors within the cryostat.
Abstract: We describe a cryogenic instrumentation platform incorporating commercially-available field-programmable gate arrays (FPGAs) configured to operate well beyond their specified temperature range. The instrument enables signal routing, multiplexing, and complex digital signal processing at temperatures approaching 4 kelvin and in close proximity to cooled devices or detectors within the cryostat. The cryogenic performance of the system is evaluated, including clock speed, error rates, and power consumption. Although constructed for the purpose of controlling and reading out quantum computing devices with low latency, the instrument is generic enough to be of broad use in a range of cryogenic applications.

Posted Content
Bin Wang, Xi Zhu, Gao Chao, Y. Bai, Junkai Dong, Lai Wang 
TL;DR: A frequency reference dissemination and synchronisation scheme in which the phase-noise compensation function is applied at the client site, thus forming a star-shaped topology to satisfy the SKA requirements.
Abstract: The Square Kilometer Array (SKA) is an international effort to build the world's largest radio telescope, with one square kilometer collecting area. Besides its ambitious scientific objectives, such as probing the cosmic dawn and cradle of life, SKA also demands several revolutionary technological breakthroughs, with ultra-high precision synchronisation of the frequency references for thousands of antennas being one of them. In this report, aimed at applications to SKA, we demonstrate a frequency reference synchronization and dissemination scheme with the phase noise compensation function placed at the client site. Hence, one central hub can be linked to a large number of client sites, forming a star-shaped topology. As a performance test, the 100 MHz reference signal from a Hydrogen maser clock is disseminated and recovered at two remote sites. Phase noise characteristics of the recovered reference frequency signal coincides with that of the hydrogen-maser source and satisfies SKA requirement.

Journal ArticleDOI
TL;DR: In this paper, a mesh of silicon photonics Mach-Zehnder interferometers is used to self-configure and reset itself after significantly perturbing the mixing, without turning off the beams.
Abstract: Propagation of light beams through scattering or multimode systems may lead to randomization of the spatial coherence of the light. Although information is not lost, its recovery requires a coherent interferometric reconstruction of the original signals, which have been scrambled into the modes of the scattering system. Here, we show that we can automatically unscramble four optical beams that have been arbitrarily mixed in a multimode waveguide, undoing the scattering and mixing between the spatial modes through a mesh of silicon photonics Mach-Zehnder interferometers. Using embedded transparent detectors and a progressive tuning algorithm, the mesh self-configures automatically and reset itself after significantly perturbing the mixing, without turning off the beams. We demonstrate the recovery of four separate 10 Gbits/s information channels, with residual cross-talk between beams of -20dB. This principle of self-configuring and self-resetting in optical systems should be applicable in a wide range of optical applications.

Journal ArticleDOI
TL;DR: In this paper, a spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm was performed using continuous and pulsed 12 keV electron beams.
Abstract: A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd excimer continuum. Various additional emission features were found. The time structure of the light emission has been measured for a set of well defined wavelength positions. The results help to interpret literature data in the context of liquid rare gas detectors in which the wavelength information is lost due to the use of wavelength shifters.

Posted Content
TL;DR: The Daya Bay experiment as discussed by the authors was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\bar{ u}_e$ oscillations over km-baselines.
Abstract: The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\bar{ u}_e$ oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of $\rm{sin}^22\theta_{13}$ and the effective mass splitting $\Delta m_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes (PMTs), the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors' baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This paper describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.

Journal ArticleDOI
TL;DR: In this article, a boron-loaded liquid scintillator detector within a water Cherenkov detector was used to suppress and measure the rate of neutron-induced background events.
Abstract: Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.

Journal ArticleDOI
TL;DR: In this paper, the authors evaluated the performance of a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner using LYSO crystal arrays with a pitch of 1 mm pitch and 12 mm in height.
Abstract: Hyperion-IID is a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. To read out the scintillation light of the employed LYSO crystal arrays with a pitch of 1 mm pitch and 12 mm in height, digital silicon photomultipliers (DPC 3200-22, Philips Digital Photon Counting) (DPC) are used. The basic PET performance in terms of energy resolution, coincidence resolution time (CRT) and sensitivity as a function of operating parameters, such as the operating temperature, the applied overvoltage, activity and configuration parameters of the DPCs, were evaluated on system level. The measured energy resolution did not show a large dependency on the selected parameters and is in the range of 12.4-12.9% for low activities and degrades to ~13.6% at activities of ~100 MBq. The CRT strongly depends on the selected trigger scheme (trig) of the DPCs. We measured approximately 260 ps, 440 ps, 540 ps and 1300 ps for trig 1-4, respectively. The trues sensitivity for a NEMA NU 4 mouse-sized scatter phantom with a 70-mm-long tube of activity was dependent on the operating parameters and was determined to be 0.4-1.4% at low activities. The random fraction stayed below 5% at activities up to 100 MBq and the scatter fraction was evaluated as ~6% for an energy window of 411-561 keV and ~16% for 250-625 keV. Furthermore, we performed imaging experiments using a mouse-sized hot-rod phantom and a large rabbit-sized phantom. In 2D slices of the reconstructed mouse-sized hot-rod phantom ({\O} = 28 mm), the rods were distinguishable from each other down to a rod size of 0.8 mm. There was no benefit of the better CRT of trig 1 over trig 3, where in the larger rabbit-sized phantom ({\O} = 114 mm), we could show a clear improvement of image quality using the time-of-flight information.

Journal ArticleDOI
TL;DR: In this paper, a two-phase liquid argon time projection chamber (LAr TPC) was used to measure the CNO neutrino rate with 15% precision.
Abstract: Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the "neutrino floor" (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ~15% precision, and significantly improve the precision of the 7Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.

Posted Content
TL;DR: The Watchman project as discussed by the authors uses a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector placed 13 kilometers from a civil nuclear reactor in the United States.
Abstract: This article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational status of the reactor, providing a firstever demonstration of the potential of large Gd-doped water detectors for remote reactor monitoring for future international nuclear nonproliferation applications. A demonstration of remote monitoring of a reactor has been called for in the U.S. National Nuclear Security Adminstration’s (NNSA) Strategic Plan [1].

Journal ArticleDOI
TL;DR: In this article, a table-top vacuum ultraviolet (VUV) laser with $113.778$nm wavelength (10.897eV) was developed for high resolution angle-resolved photoemission spectroscopy (ARPES).
Abstract: We developed a table-top vacuum ultraviolet (VUV) laser with $113.778$nm wavelength (10.897eV) and demonstrated its viability as a photon source for high resolution angle-resolved photoemission spectroscopy (ARPES). This sub-nanosecond pulsed VUV laser operates at a repetition rate of 10MHz, provides a flux of 2$\times$10$^{12}$ photons/second, and enables photoemission with energy and momentum resolutions better than 2meV and 0.012A$^{-1}$, respectively. Space-charge induced energy shifts and spectral broadenings can be reduced below 2meV. The setup reaches electron momenta up to 1.2A$^{-1}$, granting full access to the first Brillouin zone of most materials. Control over the linear polarization, repetition rate, and photon flux of the VUV source facilitates ARPES investigations of a broad range of quantum materials, bridging the application gap between contemporary low energy laser-based ARPES and synchrotron-based ARPES. We describe the principles and operational characteristics of this source, and showcase its performance for rare earth metal tritellurides, high temperature cuprate superconductors and iron-based superconductors.