scispace - formally typeset
Journal ArticleDOI

On the Reduction of Second Harmonic Current and Improvement of Dynamic Response for Two-Stage Single-Phase Inverter

TLDR
Based on the current mode control and load current feed forward, two control methods to achieve low SHC in the front-end dc-dc converter and fast dynamic performance during load transient are proposed.
Abstract
Two-stage single-phase inverters have been widely used as they can achieve voltage matching and galvanic isolation between the input and output. Due to the pulsating output power of the downstream inverter, an ac current at twice the output frequency, which is called second harmonic current (SHC), arises in the input side of the downstream inverter. This SHC will penetrate to the front-end dc-dc converter, leading to reduced conversion efficiency. This paper first analyzes the propagation mechanism of the SHC and load transient response of two-stage single-phase inverters from the viewpoint of output impedance. Then, based on the current mode control and load current feed forward, two control methods to achieve low SHC in the front-end dc-dc converter and fast dynamic performance during load transient are proposed in this paper. Finally, a 2-kW two-stage single-phase inverter prototype has been constructed and tested, and the experimental results are provided to verify the effectiveness of the proposed control methods.

read more

Citations
More filters
Journal ArticleDOI

Low-Frequency Power Decoupling in Single-Phase Applications: A Comprehensive Overview

TL;DR: In this paper, the authors present a literature overview of power decoupling in single-phase applications and present the best reference on this topic, which can be implemented as series or parallel with respect to the ac, dc or link side.
Journal ArticleDOI

Control Schemes for Reducing Second Harmonic Current in Two-Stage Single-Phase Converter: An Overview From DC-Bus Port-Impedance Characteristics

TL;DR: Critical points for SHC reduction are summarized, indicating that, for reducing SHC in BVCC, proper control scheme needs be incorporated for increasing the dc-bus port-impedance at twice the input frequency and simultaneously, the loop gain should be high enough for eliminating theSHC in the dc source or load.
Journal ArticleDOI

Second-Harmonic Current Reduction for Two-Stage Inverter With Boost-Derived Front-End Converter: Control Schemes and Design Considerations

TL;DR: In this paper, a two-stage single-phase inverter with a boost-derived front-end converter was designed to reduce the second-harmonic current (SHC) by using virtual series impedance.
Journal ArticleDOI

Modeling and Design of an Oscillatory Current-Sharing Control Strategy in DC Microgrids

TL;DR: This paper presents an effective control scheme in dc microgrids to precisely share the load current oscillatory and dc components among distributed generation (DG) units by assigning appropriate output impedance values and droop coefficients to each DG unit.
Journal ArticleDOI

Analysis and Fault Control of Hybrid Modular Multilevel Converter With Integrated Battery Energy Storage System

TL;DR: In this paper, a hybrid multilevel converter (MMC) integrated with split battery modules has been verified a better choice for the large-scale battery energy storage system (BESS), in which both ac grid and dc grid can exchange power with the BESS while the power transfer between ac and dc grids can be decoupled.
References
More filters
Journal ArticleDOI

Topologies of single-phase inverters for small distributed power generators: an overview

TL;DR: In this paper, an overview of single-phase inverters developed for small distributed power generators is presented, compared, and evaluated against the requirements of power decoupling and dual-grounding, the capabilities for grid-connected or/and stand-alone operations, and specific DG applications.
Proceedings ArticleDOI

Design considerations for high-voltage high-power full-bridge zero-voltage-switched PWM converter

TL;DR: In this article, a steady-state analysis is presented with complete characterization of the converter operation and the design procedures based on the analysis are presented and the various losses in the circuit assessed.

Average current mode control of switching power supplies

L. H. Dixon
TL;DR: Average current mode control may be used effectively to control currents other than inductor current, allowing a much broader range of topological application.
Journal ArticleDOI

Flyback-Type Single-Phase Utility Interactive Inverter With Power Pulsation Decoupling on the DC Input for an AC Photovoltaic Module System

TL;DR: In this paper, a flyback-type utility interactive inverter circuit topology was proposed for photovoltaic (PV) power generation systems when its lifetime under high atmospheric temperature is taken into account.
Journal ArticleDOI

Minimum Energy and Capacitance Requirements for Single-Phase Inverters and Rectifiers Using a Ripple Port

TL;DR: In this article, a ripple power port is proposed to manage energy storage and decouple capacitor ripple from power ripple, allowing the designer to make a choice of capacitor voltage independent of other system voltages.
Related Papers (5)