Journal ArticleDOI
Data Reduction and Error Analysis for the Physical Sciences.
TLDR
Numerical methods matrices graphs and tables histograms and graphs computer routines in Pascal and Monte Carlo techniques dependent and independent variables least-squares fit to a polynomial least-square fit to an arbitrary function fitting composite peaks direct application of the maximum likelihood.Abstract:
Uncertainties in measurements probability distributions error analysis estimates of means and errors Monte Carlo techniques dependent and independent variables least-squares fit to a polynomial least-squares fit to an arbitrary function fitting composite peaks direct application of the maximum likelihood. Appendices: numerical methods matrices graphs and tables histograms and graphs computer routines in Pascal.read more
Citations
More filters
Journal ArticleDOI
Monitoring carnivore populations at the landscape scale: occupancy modelling of tigers from sign surveys.
Kota Ullas Karanth,Arjun M. Gopalaswamy,Arjun M. Gopalaswamy,Narayanarao Samba Kumar,Srinivas Vaidyanathan,James D. Nichols,Darryl I. MacKenzie +6 more
TL;DR: In this article, the authors used a spatially replicated survey to estimate habitat occupancy for a tiger Panthera tigris metapopulation across a c. 38,000-km2 landscape in India.
Journal ArticleDOI
The Soft Gamma-Ray Spectral Variability of Cygnus X-1
Mark L. McConnell,Andrzej A. Zdziarski,K. Bennett,H. Bloemen,Werner Collmar,W. Hermsen,L. Kuiper,W. S. Paciesas,Bernard F. Phlips,Juri Poutanen,James M. Ryan,V. Schönfelder,Helmut Steinle,Andrew W. Strong +13 more
TL;DR: In this paper, the authors used observations of Cyg X-1 from the Compton Gamma Ray Observatory and BeppoSAX to study the variation in the MeV γ-ray emission between the hard and soft spectral states, using spectra that cover the energy range from 20 keV up to 10 MeV.
Journal ArticleDOI
Analysis of clinical complication data for radiation hepatitis using a parallel architecture model
A. Jackson,R.K. Ten Haken,John M. Robertson,Marc L. Kessler,G.J. Kutcher,Theodore S. Lawrence +5 more
TL;DR: The observed radiation hepatitis complications show a threshold effect that can be described well with a parallel architecture model, however, additional independent studies are required to better determine the parameters defining the functional reserve distribution and subunit radiosensitivity.
Journal ArticleDOI
Quantitation of microRNAs using a modified Invader assay
Hatim T. Allawi,James E. Dahlberg,Sarah M. Olson,Elsebet Lund,Marilyn C. Olson,Wupo Ma,Tsetska Y. Takova,Bruce Neri,Victor I. Lyamichev +8 more
TL;DR: The Invader miRNA assay, which can be performed in unfractionated detergent lysates, uses fluorescence detection in microtiter plates and requires only 2-3 h incubation time, allowing for parallel analysis of multiple samples in high-throughput screening analyses.
Journal ArticleDOI
Development of a sensor for temperature and water concentration in combustion gases using a single tunable diode laser
TL;DR: In this article, the water vapour spectrum in the 1-2 µm near-infrared region is systematically analyzed to find the best absorption transitions for sensitive measurement of H2O concentration and temperature in combustion environments using a single tunable diode laser with typical distributed feedback single-mode scanning range (1 cm−1).