Projection angle dependence in grating-based X-ray dark-field imaging of ordered structures

Reads0
Chats0
TLDR
This contribution attempts to extend existing models for 2D projections to 3D data by analyzing dark-field contrast tomography of anisotropically structured materials such as carbon fiber reinforced carbon (CFRC).
Abstract
Over the recent years X-ray differential phase-contrast imaging was developed for the hard X-ray regime as produced from laboratory X-ray sources. The technique uses a grating-based Talbot-Lau interferometer and was shown to yield image contrast gain, which makes it very interesting to the fields of medical imaging and non-destructive testing, respectively. In addition to X-ray attenuation contrast, the differential phase-contrast and dark-field images provide different structural information about a specimen. For the dark-field even at length scales much smaller than the spatial resolution of the imaging system. Physical interpretation of the dark-field information as present in radiographic and tomographic (CT) images requires a detailed look onto the geometric orientation between specimen and the setup. During phase-stepping the drop in intensity modulation, due to local scattering effects within the specimen is reproduced in the dark-field signal. This signal shows strong dependencies on micro-porosity and micro-fibers if these are numerous enough in the object. Since a grating-interferometer using a common unidirectional line grating is sensitive to X-ray scattering in one plane only, the dark-field image is influenced by the fiber orientations with respect to the grating bars, which can be exploited to obtain anisotropic structural information. With this contribution, we attempt to extend existing models for 2D projections to 3D data by analyzing dark-field contrast tomography of anisotropically structured materials such as carbon fiber reinforced carbon (CFRC).

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Talbot-Lau x-ray phase-contrast setup for fast scanning of large samples

TL;DR: An improved reconstruction algorithm concerning the scanning approach, which increases robustness with respect to mechanical instabilities, has been developed and is presented and the resolution of the setup in dependence of the scanning velocity is evaluated.
Journal ArticleDOI

Non-Destructive Testing of Archaeological Findings by Grating-Based X-Ray Phase-Contrast and Dark-Field Imaging

TL;DR: X-ray grating interferometry is considered as a non-destructive and advanced X-ray imaging method to retrieve more information about archaeological findings and it is proved that the combination of the attenuation and the dark-field image in particular, enables a separation of structural properties for fabric remnants.
Journal ArticleDOI

Six dimensional X-ray Tensor Tomography with a compact laboratory setup

TL;DR: In this paper, the authors combine the anisotropic dark-field signal obtained in a grating interferometer and advanced tomographic reconstruction methods to reconstruct a six dimensional scattering tensor at every spatial location in 3D.
Journal ArticleDOI

A new method for fusion, denoising and enhancement of x-ray images retrieved from Talbot-Lau grating interferometry.

TL;DR: The new framework for the processing of AC, DPC and DFC allows the most relevant features of all three images to be combined in one image while reducing the noise and enhancing adaptively the relevant image features.
Journal ArticleDOI

High-energy x-ray Talbot–Lau radiography of a human knee

TL;DR: This measurement, for the first time, proves the feasibility of Talbot-Lau x-ray imaging at high-energy spectra above 40 kVp and reasonable dose levels with regard to spacious and dense objects.
References
More filters
Journal ArticleDOI

X-ray phase imaging with a grating interferometer.

TL;DR: Using a high-efficiency grating interferometer for hard X rays (10-30 keV) and a phase-stepping technique, separate radiographs of the phase and absorption profiles of bulk samples can be obtained from a single set of measurements.
Journal ArticleDOI

Hard-X-ray dark-field imaging using a grating interferometer

TL;DR: This letter reports a new approach on the basis of a grating interferometer that can efficiently yield dark-field scatter images of high quality, even with conventional X-ray tube sources and is fully compatible with conventional transmission radiography and a recently developed hard-X-ray phase-contrast imaging scheme.
Journal ArticleDOI

Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays.

TL;DR: In this article, a holographic reconstruction procedure combining images taken at different distances from the specimen was developed, which results in quantitative phase mapping and, through association with threedimensional reconstruction, in holotomography, the complete three-dimensional mapping of the density in a sample.
Journal ArticleDOI

On the origin of visibility contrast in x-ray Talbot interferometry

TL;DR: The visibility-reduction contrast observed by x-ray grating interferometry can be understood in relation to the structural parameters of the microstructures, and the relation between the three parameters and the features of the micron-sized structures is discussed.
Journal ArticleDOI

Phase Tomography by X-ray Talbot Interferometry for Biological Imaging

TL;DR: The X-ray phase tomography of biological samples is reported in this paper, which is based on Xray Talbot interferometry, and imaging results obtained for a cancerous rabbit liver and a mouse tail with synchrotron radiation are presented.
Related Papers (5)