scispace - formally typeset
Journal ArticleDOI

ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs – Threshold Doses for Tissue Reactions in a Radiation Protection Context

Reads0
Chats0
TLDR
Estimates of ‘practical’ threshold doses for tissue injury defined at the level of 1% incidence are provided and it appears that the rate of dose delivery does not modify the low incidence for reactions manifesting very late after low total doses, particularly for cataracts and circulatory disease.
Abstract
This report provides a review of early and late effects of radiation in normal tissues and organs with respect to radiation protection. It was instigated following a recommendation in Publication 103 (ICRP, 2007), and it provides updated estimates of 'practical' threshold doses for tissue injury defined at the level of 1% incidence. Estimates are given for morbidity and mortality endpoints in all organ systems following acute, fractionated, or chronic exposure. The organ systems comprise the haematopoietic, immune, reproductive, circulatory, respiratory, musculoskeletal, endocrine, and nervous systems; the digestive and urinary tracts; the skin; and the eye. Particular attention is paid to circulatory disease and cataracts because of recent evidence of higher incidences of injury than expected after lower doses; hence, threshold doses appear to be lower than previously considered. This is largely because of the increasing incidences with increasing times after exposure. In the context of protection, it is the threshold doses for very long follow-up times that are the most relevant for workers and the public; for example, the atomic bomb survivors with 40-50years of follow-up. Radiotherapy data generally apply for shorter follow-up times because of competing causes of death in cancer patients, and hence the risks of radiation-induced circulatory disease at those earlier times are lower. A variety of biological response modifiers have been used to help reduce late reactions in many tissues. These include antioxidants, radical scavengers, inhibitors of apoptosis, anti-inflammatory drugs, angiotensin-converting enzyme inhibitors, growth factors, and cytokines. In many cases, these give dose modification factors of 1.1-1.2, and in a few cases 1.5-2, indicating the potential for increasing threshold doses in known exposure cases. In contrast, there are agents that enhance radiation responses, notably other cytotoxic agents such as antimetabolites, alkylating agents, anti-angiogenic drugs, and antibiotics, as well as genetic and comorbidity factors. Most tissues show a sparing effect of dose fractionation, so that total doses for a given endpoint are higher if the dose is fractionated rather than when given as a single dose. However, for reactions manifesting very late after low total doses, particularly for cataracts and circulatory disease, it appears that the rate of dose delivery does not modify the low incidence. This implies that the injury in these cases and at these low dose levels is caused by single-hit irreparable-type events. For these two tissues, a threshold dose of 0.5Gy is proposed herein for practical purposes, irrespective of the rate of dose delivery, and future studies may elucidate this judgement further.

read more

Citations
More filters
Journal ArticleDOI

Assessment of radiation dose for dental workers in Saudi Arabia (2015–2019)

TL;DR: The annual average effective dose, averaged over the five years, was found to be 0.72 mSv, which is a good indicator of dental radiation safety practices in Saudi Arabia.
Journal ArticleDOI

Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures

TL;DR: In this paper , a review summarises the different uses of notifications and alerts to help in optimisation for CT and for fluoroscopy-guided interventional procedures as well as in the analysis of unintended and accidental medical exposures.
Journal ArticleDOI

Eye lens doses of radiology technologists who assist patients during radiography.

TL;DR: Evaluating the amounts of radiation to which the eye lenses of radiological technologists (RT) become exposed and the effects of wearing lead glasses on dose reduction while assisting patients during radiographic assessments found that Hp(3) for RT might exceed the revised eye equivalent dose limit 20 mSv/y recommended by the ICRP.
Journal ArticleDOI

Cone-beam computed tomography imaging: therapeutic staff dose during chemoembolisation procedure.

TL;DR: Personal-dose-equivalent (PDE) and annual-personal-dose (APD) from absorbed dose based on international atomic energy agency protocol were estimated and were within the recommended ICRP-103 annual limit.
Journal ArticleDOI

Application of Volumetric Modulated Arc Therapy and Simultaneous Integrated Boost Techniques to Prepare "Safe Margin" in the Rabbit VX2 Limb Tumor Model.

TL;DR: The feasibility of using VMAT-SIB technique in the rabbit VX2 limb tumor model is demonstrated and the formation of a necrotic zone can be effectively defined as safe margin in the GTVboost area.
References
More filters
Journal ArticleDOI

Apoptosis: A Review of Programmed Cell Death

TL;DR: The goal of this review is to provide a general overview of current knowledge on the process of apoptosis including morphology, biochemistry, the role of apoptoses in health and disease, detection methods, as well as a discussion of potential alternative forms of apoptotic proteins.
Journal ArticleDOI

Inflammation in atherosclerosis

TL;DR: The new appreciation of the role of inflammation in atherosclerosis provides a mechanistic framework for understanding the clinical benefits of lipid-lowering therapies and unravelling the details of inflammatory pathways may eventually furnish new therapeutic targets.
Related Papers (5)