scispace - formally typeset
Journal ArticleDOI

ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs – Threshold Doses for Tissue Reactions in a Radiation Protection Context

Reads0
Chats0
TLDR
Estimates of ‘practical’ threshold doses for tissue injury defined at the level of 1% incidence are provided and it appears that the rate of dose delivery does not modify the low incidence for reactions manifesting very late after low total doses, particularly for cataracts and circulatory disease.
Abstract
This report provides a review of early and late effects of radiation in normal tissues and organs with respect to radiation protection. It was instigated following a recommendation in Publication 103 (ICRP, 2007), and it provides updated estimates of 'practical' threshold doses for tissue injury defined at the level of 1% incidence. Estimates are given for morbidity and mortality endpoints in all organ systems following acute, fractionated, or chronic exposure. The organ systems comprise the haematopoietic, immune, reproductive, circulatory, respiratory, musculoskeletal, endocrine, and nervous systems; the digestive and urinary tracts; the skin; and the eye. Particular attention is paid to circulatory disease and cataracts because of recent evidence of higher incidences of injury than expected after lower doses; hence, threshold doses appear to be lower than previously considered. This is largely because of the increasing incidences with increasing times after exposure. In the context of protection, it is the threshold doses for very long follow-up times that are the most relevant for workers and the public; for example, the atomic bomb survivors with 40-50years of follow-up. Radiotherapy data generally apply for shorter follow-up times because of competing causes of death in cancer patients, and hence the risks of radiation-induced circulatory disease at those earlier times are lower. A variety of biological response modifiers have been used to help reduce late reactions in many tissues. These include antioxidants, radical scavengers, inhibitors of apoptosis, anti-inflammatory drugs, angiotensin-converting enzyme inhibitors, growth factors, and cytokines. In many cases, these give dose modification factors of 1.1-1.2, and in a few cases 1.5-2, indicating the potential for increasing threshold doses in known exposure cases. In contrast, there are agents that enhance radiation responses, notably other cytotoxic agents such as antimetabolites, alkylating agents, anti-angiogenic drugs, and antibiotics, as well as genetic and comorbidity factors. Most tissues show a sparing effect of dose fractionation, so that total doses for a given endpoint are higher if the dose is fractionated rather than when given as a single dose. However, for reactions manifesting very late after low total doses, particularly for cataracts and circulatory disease, it appears that the rate of dose delivery does not modify the low incidence. This implies that the injury in these cases and at these low dose levels is caused by single-hit irreparable-type events. For these two tissues, a threshold dose of 0.5Gy is proposed herein for practical purposes, irrespective of the rate of dose delivery, and future studies may elucidate this judgement further.

read more

Citations
More filters
Journal ArticleDOI

VirtualDose-IR: a cloud-based software for reporting organ doses in interventional radiology

TL;DR: The results validate the accuracy of organ doses reported by VirtualDose-IR, based on a comprehensive database of Monte Carlo-generated organ dose built with a set of 21 anatomically realistic patient phantoms.
Journal ArticleDOI

Incidence risks for cerebrovascular diseases and types of stroke in a cohort of Mayak PA workers

TL;DR: CeVD incidence and some types of stroke in a cohort of Russian Mayak nuclear workers chronically exposed to ionising radiation and followed up until the end of 2018 are reported and no significant associations of either stroke or its types with cumulative gamma-ray dose of external exposure or alpha-particle dose of internal exposure were found.
Journal ArticleDOI

Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy

TL;DR: The existence of significant correlations between the eye and neck dose measurement and CT-related parameters found in physicians is proved, and it is suggested that the physician involved in CTF use a direct eye dosimeter such as the DOSIRIS for the accurate evaluation of their eye lens dose.
Journal ArticleDOI

Surgeon's and Patient's Radiation Exposure Through Vertebral Body Cement Augmentation Procedures: A Prospective Multicentric Study of 49 Cases.

TL;DR: In this article, the authors evaluated the level of radiation exposure of the spine surgeon and the patient during percutaneous procedures and found that the exposure dose to the eye exceeds the annual limit after 3500 procedures.
Journal ArticleDOI

Assessment of organ and effective dose when using region-of-interest attenuators in cone-beam CT and interventional fluoroscopy.

TL;DR: Evidence of a substantial reduction of organ and effective doses when using an ROI attenuator during CBCT and fluoroscopic procedures is provided.
References
More filters
Journal ArticleDOI

Apoptosis: A Review of Programmed Cell Death

TL;DR: The goal of this review is to provide a general overview of current knowledge on the process of apoptosis including morphology, biochemistry, the role of apoptoses in health and disease, detection methods, as well as a discussion of potential alternative forms of apoptotic proteins.
Journal ArticleDOI

Inflammation in atherosclerosis

TL;DR: The new appreciation of the role of inflammation in atherosclerosis provides a mechanistic framework for understanding the clinical benefits of lipid-lowering therapies and unravelling the details of inflammatory pathways may eventually furnish new therapeutic targets.
Related Papers (5)