Test sensitivity is secondary to frequency and turnaround time for COVID-19 screening.

TLDR
It is demonstrated that effective screening depends largely on frequency of testing and speed of reporting and is only marginally improved by high test sensitivity, and should prioritize accessibility, frequency, and sample-to-answer time.
Abstract
The COVID-19 pandemic has created a public health crisis. Because SARS-CoV-2 can spread from individuals with presymptomatic, symptomatic, and asymptomatic infections, the reopening of societies and the control of virus spread will be facilitated by robust population screening, for which virus testing will often be central. After infection, individuals undergo a period of incubation during which viral titers are too low to detect, followed by exponential viral growth, leading to peak viral load and infectiousness and ending with declining titers and clearance. Given the pattern of viral load kinetics, we model the effectiveness of repeated population screening considering test sensitivities, frequency, and sample-to-answer reporting time. These results demonstrate that effective screening depends largely on frequency of testing and speed of reporting and is only marginally improved by high test sensitivity. We therefore conclude that screening should prioritize accessibility, frequency, and sample-to-answer time; analytical limits of detection should be secondary.

read more

Citations
More filters
Posted Content

Modified Dorfman procedure for pool tests with dilution -- COVID-19 case study

TL;DR: A simple modification of Dorfman pool testing procedure in which test of a pool with negative result is independently repeated up to several times significantly reduces the number of false negatives and makes the proposed procedure an interesting choice for screening tests in the case of diseases like COVID-19.
Posted ContentDOI

A multiplexed, paired-pooled droplet digital PCR assay for detection of SARS-CoV-2 in saliva

TL;DR: In this paper , the authors developed a multiplexed, paired-pool droplet digital PCR (MP4) screening assay for the SARS-CoV-2 pandemic.
Posted ContentDOI

Community vaccination can shorten the COVID-19 isolation period: an individual-based modeling approach

TL;DR: The isolation duration of a vaccine breakthrough infector could be safely shortened if a majority of people in the community are immune to SARS-CoV-2 infection.
Journal ArticleDOI

Trade-off Between Quarantine Length and Compliance to Optimize COVID-19 Control

TL;DR: In this paper , the authors used a deterministic transmission model to identify the optimal length of quarantine to minimize transmission and modeled the relation between noncompliance behavior and disease risk using a time-varying function of leaving quarantine based on studies from the literature.
Journal ArticleDOI

Prospective Clinical Evaluation of the Diagnostic Accuracy of a Highly Sensitive Rapid Antigen Test Using Silver Amplification Technology for Emerging SARS-CoV-2 Variants

TL;DR: In this paper , the clinical usefulness of the FUJIFILM COVID-19 Ag test, an antigen test based on silver amplification and immunochromatographic technology, was tested.
References
More filters
Journal ArticleDOI

The Incubation Period of Coronavirus Disease 2019 (COVID-19) From Publicly Reported Confirmed Cases: Estimation and Application.

TL;DR: The results support current proposals for the length of quarantine or active monitoring of persons potentially exposed to SARS-CoV-2, although longer monitoring periods might be justified in extreme cases.
Journal ArticleDOI

Temporal dynamics in viral shedding and transmissibility of COVID-19.

TL;DR: It is estimated that 44% (95% confidence interval, 25–69%) of secondary cases were infected during the index cases’ presymptomatic stage, in settings with substantial household clustering, active case finding and quarantine outside the home.
Journal ArticleDOI

Sensitivity of Chest CT for COVID-19: Comparison to RT-PCR

TL;DR: In a series of 51 patients with chest CT and real-time polymerase chain reaction assay (RT-PCR) performed within 3 days, the sensitivity of CT for 2019 novel coronavirus infection was 98% and that ...