scispace - formally typeset
Open AccessJournal ArticleDOI

Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

Reads0
Chats0
TLDR
This work bridges the technological gap between signal transduction, conditioning, processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.
Abstract
Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Flexible quasi-solid-state planar micro-supercapacitor based on cellular graphene films

TL;DR: A quasi-solid-state micro-supercapacitor with cellular graphene film as the active material and polyvinyl alcohol/H3PO4 as the gel electrolyte is demonstrated as a new type of flexible energy storage device.
Journal ArticleDOI

Weaving Sensing Fibers into Electrochemical Fabric for Real‐Time Health Monitoring

TL;DR: In this paper, a new and general strategy of making electrochemical fabric from sensing fiber units is reported, which is highly flexible and maintains structural integrity and detection ability under repeated deformations, including bending and twisting.
Journal ArticleDOI

Bioinspired Composite Microfibers for Skin Adhesion and Signal Amplification of Wearable Sensors.

TL;DR: A facile approach is proposed for superior conformation and adhesion of wearable sensors to dry and wet skin and the signal-to-noise ratio of the strain sensor is significantly improved because of the considerable signal amplification of microfibrillar skin-adhesive films.
References
More filters
Journal ArticleDOI

Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes

TL;DR: Transparent, conducting spray-deposited films of single-walled carbon nanotubes are reported that can be rendered stretchable by applying strain along each axis, and then releasing this strain.
Journal ArticleDOI

An ultra-lightweight design for imperceptible plastic electronics

TL;DR: In this paper, the authors present a platform that makes electronics both virtually unbreakable and imperceptible on polyimide polysilicon elastomers, which can be operated at high temperatures and in aqueous environments.
Journal ArticleDOI

A review of wearable sensors and systems with application in rehabilitation.

TL;DR: In this paper, a review of wearable sensors and systems that are relevant to the field of rehabilitation is presented, focusing on health and wellness, safety, home rehabilitation, assessment of treatment efficacy, and early detection of disorders.
Journal ArticleDOI

Piezoelectricity of single-atomic-layer MoS2 for energy conversion and piezotronics.

TL;DR: It is shown that cyclic stretching and releasing of thin MoS2 flakes with an odd number of atomic layers produces oscillating piezoelectric voltage and current outputs, whereas no output is observed for flakes with even number of layers, which may enable the development of applications in powering nanodevices, adaptive bioprobes and tunable/stretchable electronics/optoelectronics.
Journal ArticleDOI

Electrochemical Biosensors - Sensor Principles and Architectures

TL;DR: In this article, the most common traditional traditional techniques, such as cyclic voltammetry, chronoamperometry, chronopotentiometry, impedance spectroscopy, and various field-effect transistor based methods are presented along with selected promising novel approaches, including nanowire or magnetic nanoparticle-based biosensing.