Papers published on a yearly basis
Papers
More filters
••
TL;DR: In this paper, ground-based spectral data were obtained for single crowns of balsam fir trees with varying degrees of current defoliation caused by feeding of the spruce budworm [Choristoneura fumiferana (Clem.)].
25 citations
••
TL;DR: In this article, stainless steels such as 310H and 304H were tested for their SCWR corrosion resistance and microstructure stability under the proposed reactor operating condition, and the results indicated that these alloy is promising for in-core applications.
25 citations
••
TL;DR: Software, the Automated Dicentric Chromosome Identifier (ADCI), is presented which detects and discriminates DCs from monocentric chromosomes, computes biodosimetry calibration curves and estimates radiation dose.
Abstract: The dose from ionizing radiation exposure can be interpolated from a calibration curve fit to the frequency of dicentric chromosomes (DCs) at multiple doses. As DC counts are manually determined, there is an acute need for accurate, fully automated biodosimetry calibration curve generation and analysis of exposed samples. Software, the Automated Dicentric Chromosome Identifier (ADCI), is presented which detects and discriminates DCs from monocentric chromosomes, computes biodosimetry calibration curves and estimates radiation dose. Images of metaphase cells from samples, exposed at 1.4-3.4 Gy, that had been manually scored by two reference laboratories were reanalyzed with ADCI. This resulted in estimated exposures within 0.4-1.1 Gy of the physical dose. Therefore, ADCI can determine radiation dose with accuracies comparable to standard triage biodosimetry. Calibration curves were generated from metaphase images in ~10 h, and dose estimations required ~0.8 h per 500 image sample. Running multiple instances of ADCI may be an effective response to a mass casualty radiation event.
25 citations
••
TL;DR: Pebble bed ceramic breeders have been under development in Canada for over ten years as mentioned in this paper, with the main focus on 1.2 mm diameter Li2ZrO3 and Li2TiO3 pebbles.
25 citations
••
TL;DR: In this paper, the authors used the EVPSC-TDT model for polycrystal plasticity and in-situ neutron diffraction to investigate the behavior of a Mg-8.5wt.%Al alloy with two starting textures.
25 citations
Authors
Showing all 2298 results
Name | H-index | Papers | Citations |
---|---|---|---|
Michael D. Guiver | 78 | 288 | 20540 |
Robert J. Birgeneau | 78 | 587 | 22686 |
Mike D. Flannigan | 71 | 211 | 21327 |
Martin T. Dove | 61 | 396 | 14767 |
Luis Rodrigo | 58 | 341 | 12963 |
André Longtin | 56 | 260 | 16372 |
David Mitlin | 56 | 196 | 15479 |
John Katsaras | 55 | 220 | 9263 |
John E. Greedan | 55 | 391 | 12171 |
Gang Li | 48 | 406 | 7713 |
Matthew G. Tucker | 45 | 224 | 7288 |
Bruce D. Gaulin | 45 | 284 | 6698 |
Erick J. Dufourc | 43 | 144 | 5882 |
Norbert Kučerka | 43 | 119 | 7319 |
Stephen J. Skinner | 42 | 194 | 8522 |