scispace - formally typeset
Journal ArticleDOI

Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/s

TLDR
This study shows for the first time that normal brain tissue toxicities after WBI can be reduced with increased dose rate.
About
This article is published in Radiotherapy and Oncology.The article was published on 2017-05-22. It has received 363 citations till now.

read more

Citations
More filters
Journal ArticleDOI

Shaping of a laser-accelerated proton beam for radiobiology applications via genetic algorithm.

TL;DR: In this article, the authors demonstrate the use of a GA to design an optimal non-flat scattering system to shape the beam and efficiently flatten the transversal dose distribution at the irradiated target.
Journal ArticleDOI

Proton FLASH effects on mouse skin at different oxygen tensions

TL;DR: In this article , double scattering proton system provided a 1.2 × 1.6 cm2 elliptical field at a dose rate of ∼130 Gy s−1, and the legs of the FVB/N mice were marked with two tattooed dots.
Journal ArticleDOI

A 60 MeV proton beam-line dedicated to research and development programs.

TL;DR: In this paper , a new proton beam-line dedicated to R&D programs has been developed at CentreAntoine Lacassagne (CAL), in Nice (France), in collaboration with the Centrenational d'études spatiales (CNES).
Journal ArticleDOI

Commissioning a 250 MeV research beamline for proton FLASH radiotherapy preclinical experiments.

TL;DR: In this paper , a 2D strip ionization chamber array (SICA) with high spatiotemporal resolution was used to measure spot dwell times under various beam currents and to quantify dose rates for various field sizes.
Journal ArticleDOI

3D printing for dosimetric optimization and quality assurance in small animal irradiations using megavoltage X-rays.

TL;DR: The feasibility of modern megavoltage (MV) linear accelerator (LINAC)-based RT for small animals using easy-to-use consumer 3D printing technology for dosimetric optimization and quality assurance (QA) assessment is reported on.
References
More filters
Journal ArticleDOI

The novel object recognition memory: neurobiology, test procedure, and its modifications.

TL;DR: The neurobiology and methodological modifications of the test commonly used in behavioral pharmacology are reviewed to review the novel object recognition paradigms in animals, as a valuable measure of cognition.
Journal ArticleDOI

AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.

TL;DR: This protocol represents a major simplification compared to the AAPM's TG-21 protocol in the sense that large tables of stopping-power ratios and mass-energy absorption coefficients are not needed and the user does not need to calculate any theoretical dosimetry factors.
Journal ArticleDOI

Neuroinflammation and M2 microglia: the good, the bad, and the inflamed.

TL;DR: The multiple possible activation states microglia can be polarized to are examined and particular attention is given to utilizing M2 microglial polarization as a potential therapeutic option in treating diseases.
Journal ArticleDOI

Radiation-induced impairment of hippocampal neurogenesis is associated with cognitive deficits in young mice

TL;DR: Evidence is provided that irradiation of young animals induces a long-term impairment of dentate subgranular zone neurogenesis that is associated with hippocampal-dependent memory deficits.
Related Papers (5)