Institution
Phoenix Contact
Company•Middletown, Pennsylvania, United States•
About: Phoenix Contact is a company organization based out in Middletown, Pennsylvania, United States. It is known for research contribution in the topics: Terminal (electronics) & Clamping. The organization has 1257 authors who have published 2097 publications receiving 7673 citations. The organization is also known as: Phoenix Contact (Germany).
Papers published on a yearly basis
Papers
More filters
•
09 Oct 2012TL;DR: In this article, a terminal block for mounting on a DIN rail includes a plurality of stacked modules with each module having a contact body and an extender body mounted on the contact body.
Abstract: A terminal block for mounting on a DIN rail includes a plurality of stacked modules with each module having a contact body and an extender body mounted on the contact body. A circuit board or electronic component is mounted on the contact body and the extender body. Different size extender bodies may be mounted on a common contact body to accommodate mounting different size circuit boards or components on the block.
9 citations
•
26 Jan 2000TL;DR: In this paper, a Bussystem with optischen Energiequelle (13) and with einer Mehr oder Vielzahl von Busteilnehmern (11) is described.
Abstract: Die Erfindung betrifft ein Bussystem (10) mit einer optischen Energiequelle (13) und mit einer Mehr- oder Vielzahl von Busteilnehmern (11), die zur Ubertragung von Daten durch einen Lichtwellenleiter (12) miteinander verbunden sind, wobei die Datenubertragung und die Energieubertragung fur die Busteilnehmer (11) uber den gemeinsamen Lichtwellenleiter (12) parallel durch Modulation des Datenstroms (28) auf den Energiestrom (27) unter Erreichung eines hohen Energiegehaltes des Signals (17) und/oder durch zeitlich sequentielle Nacheinandersendung von Datenstrom (28) und Energiestrom (27) in Form von Signalen (17) erfolgt.
9 citations
•
31 Jan 2014TL;DR: In this paper, a network diagnostic module coupleable to a distributed process control network that controls an industrial process via field devices coupled to the network includes a power block coupleable with the network and configured to power the network diagnostics module with energy received from the network.
Abstract: A network diagnostic module coupleable to a distributed process control network that controls an industrial process via field devices coupled to the network includes a power block coupleable to the network and configured to power the network diagnostic module with energy received from the network, a communications block coupleable to the network and configured to bi-directionally communicate over the network, and a diagnostics block coupleable to the network and configured to make diagnostic measurements of network and protocol parameters of the network. The network diagnostic module is not itself a field device that detects or controls any process variable of the industrial process, enabling the network diagnostic module to be placed essentially anywhere along the network to permanently monitor the network.
9 citations
•
21 May 1999TL;DR: In this article, eine Vorrichtung zum elektronischen Uber-wachung des Versorgungsstromes von an einen Bus angeschlossenen Baugruppen bereitzustellen is found, in which einerseits bei Bedarf eine sichere Trennung von der Versungsspannung durchfuhrt und gleichzeitig die Diagnosefahigkeit zum Zwecke der Fehlersuche aufrechter
Abstract: Die Erfindung betrifft eine Vorrichtung zur elektronischen Uberwachung des Versorgungsstromes von an einen Bus angeschlossenen Baugruppen, insbesondere zur Uberwachung des Versorgungsstromes von Busteilnehmern eines Automatisierungsbussystems. DOLLAR A Der Erfindung liegt die Aufgabe zugrunde, eine Vorrichtung zur elektronischen Uberwachung des Versorgungsstromes von an einen Bus angeschlossenen Baugruppen bereitzustellen, welche einerseits bei Bedarf eine sichere Trennung von der Versorgungsspannung durchfuhrt und gleichzeitig die Diagnosefahigkeit zum Zwecke der Fehlersuche aufrechterhalt. DOLLAR A Dies erreicht die Erfindung dadurch, das die Vorrichtung zumindest eine Einrichtung zur Erfassung und zumindest eine Einrichtung zur Begrenzung und/oder Abschaltung des Versorgungsstromes aufweist. DOLLAR A Dabei spricht die Einrichtung zur Abschaltung des Versorgungsstromes auf den Wert des erfasten Versorgungsstromes an, womit sichergestellt ist, das die Energieversorgung fur andere Baugruppen des Automatisierungsbusses, welche bezuglich der Versorgungsspannung parallel geschaltet sind, nicht ausfallt, wodurch zumindest ein beschrankter Betrieb der Anlage aufrechterhalten bleibt und damit auch eine Fehlerdiagnose moglich bleibt.
9 citations
Authors
Showing all 1261 results
Name | H-index | Papers | Citations |
---|---|---|---|
Jurgen Jasperneite | 25 | 139 | 2208 |
Dathan Hamann | 15 | 42 | 639 |
Heinz Reibke | 11 | 58 | 277 |
Eberhard Dipl Ing Lehmann | 11 | 19 | 251 |
Klaus Prof Dr Ing Scheibe | 10 | 19 | 209 |
Thomas Salomon | 8 | 18 | 186 |
Martin Wetter | 8 | 42 | 146 |
Klaus Eisert | 8 | 15 | 155 |
Andreas Schrader | 8 | 28 | 185 |
Gunnar Lessmann | 7 | 34 | 131 |
Feye-Hohmann Juergen | 7 | 26 | 151 |
Rainer Durth | 7 | 25 | 154 |
Dietmar Krumsiek | 7 | 39 | 165 |
Thomas Führer | 7 | 40 | 154 |
Stefan Giefers | 7 | 19 | 184 |