Optical coherence tomography

TLDR
OCT as discussed by the authors uses low-coherence interferometry to produce a two-dimensional image of optical scattering from internal tissue microstructures in a way analogous to ultrasonic pulse-echo imaging.
Abstract
A technique called optical coherence tomography (OCT) has been developed for noninvasive cross-sectional imaging in biological systems. OCT uses low-coherence interferometry to produce a two-dimensional image of optical scattering from internal tissue microstructures in a way that is analogous to ultrasonic pulse-echo imaging. OCT has longitudinal and lateral spatial resolutions of a few micrometers and can detect reflected signals as small as approximately 10(-10) of the incident optical power. Tomographic imaging is demonstrated in vitro in the peripapillary area of the retina and in the coronary artery, two clinically relevant examples that are representative of transparent and turbid media, respectively.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes

TL;DR: Compared with fixed compensation, mean-based SLP parameters generated with SLP-VCC have greater correlation with visual function and RNFL thickness assessments obtained with OCT.
Journal ArticleDOI

Photoacoustic ocular imaging

TL;DR: A photoacoustic ocular imaging device was developed and demonstrated its utility in imaging the deeper layers of the eye including the retina, choroid, and optic nerve and was able to visualize the blood distribution of an enucleated pig's eye and an eye of a living rabbit.
Journal Article

Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system.

TL;DR: OCT is a useful tool in the monitoring of patients with conditions that affect macular thickness, even when there is considerable degradation of the OCT signal, and measurements of gap thickness were still shown to be accurate, precise, reproducible, and repeatable.
Journal Article

Intersession repeatability of macular thickness measurements with the Humphrey 2000 OCT

TL;DR: OCT measurements of macular thickness made with the Humphrey 2000 OCT system are repeatable over different sessions with an expected variation of less than 11 microm (99% confidence interval).
References
More filters
Journal ArticleDOI

Computerized transverse axial scanning (tomography): Part I. Description of system. 1973.

TL;DR: A technique in which X-ray transmission readings are taken through the head at a multitude of angles: from these data, absorption values of the material contained within the head are calculated on a computer and presented as a series of pictures of slices of the cranium.
Journal ArticleDOI

Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss.

TL;DR: Nerve fiber layer defects expanded with time, often by the development and coalescence of adjacent areas of damage, and field defects closely corresponded, but nerve fiber layer loss was generally more widespread.
Journal ArticleDOI

Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma.

TL;DR: Estimates suggest that visual field sensitivity in automated testing begins to decline soon after the initial loss of ganglion cells in human eyes with glaucoma, and that this decline is most pronounced in areas that had 0-dB sensitivity in the field test.
Related Papers (5)