01 Jul 1997
TL;DR: In this article, a fuzzy logic controlled genetic algorithm (FCGA) was applied to power system environmental/economic dispatch for a six-generator power system and the results showed that the proposed algorithm can be applied to wide range of optimisation problems.
Abstract: The paper presents the application of a fuzzy logic controlled genetic algorithm (FCGA) to power system environmental/economic dispatch. The authors first propose an improved genetic algorithm with two fuzzy controllers based on some heuristics to adaptively adjust the crossover probability and mutation rate during the optimisation process. The implementation of the fuzzy crossover and mutation controllers is described. The proposed FCGA can be applied to wide range of optimisation problems. The validity of the proposed algorithm is illustrated on environmental/economic dispatch of a six-generator power system. Its performance is compared with conventional GAs and the Newton-Raphson method. The results are very encouraging.
237 citations
••
TL;DR: In this paper, the most important factors affecting the industrial gas turbine engine performance deterioration with service time are described and some approximate data on the prediction of the rate of deterioration is provided. Recommendations are made on how to detect and monitor the performance deterioration.
Abstract: This paper describes the most important factors affecting the industrial gas turbine engine performance deterioration with service time and provides some approximate data on the prediction of the rate of deterioration. Recommendations are made on how to detect and monitor the performance deterioration. Preventative measures, which can be taken to avoid or retard the performance deterioration, are described in some detail.
237 citations
•
31 Oct 1978TL;DR: In this paper, a relay with a programmable zone and address identifying states for connection in plural repeating levels defining branch paths linking a central control terminal with multiple remote terminals via a distribution line network is presented.
Abstract: Bidirectional addressable repeaters of a power line carrier communication system each include an address recognition and a receive and transmit control logic circuit having programmable zone and address identifying states for connection in plural repeating levels defining branch paths linking a central control terminal with multiple remote terminals via a distribution line network. Each repeater retransmits an interrogation message, provides its own repeater address modification, and remains in a response-wait status. The alerted repeaters define the predetermined route of branch paths for being sequentially activated by a response message. Simplified repeater response address formats are used and each repeater modified its address data upon response message retransmission. The desired sequentially occurring repeating transmissions are assured upon retransmission of both the interrogation and response messages.
236 citations
••
02 Oct 1988TL;DR: In this paper, the authors describe the control strategy and hardware design for a 30-hp matrix converter (9-switch forced-commutation cycloconverter), which was developed for high-bandwidth four-quadrant-motor drive applications.
Abstract: A description is given of the control strategy and hardware design for a 30-hp matrix converter (9-switch forced-commutation cycloconverter), which was developed for high-bandwidth four-quadrant-motor drive applications. The switching technique ensures very low distortion of the input currents with unity fundamental displacement factor. Experimental results are presented. >
236 citations
••
TL;DR: In this article, a detailed study of oxides formed in 360 °C water on four Zr-based alloys (Zircaloy-4, ZIRLO™,1 Zr−2.5%Nb and Zr•2.9%Cu) was undertaken to relate oxide structure to corrosion performance.
235 citations
Authors
Showing all 27975 results
Name | H-index | Papers | Citations |
---|---|---|---|
Takeo Kanade | 147 | 799 | 103237 |
Martin A. Green | 127 | 1069 | 76807 |
Shree K. Nayar | 113 | 384 | 45139 |
Dieter Bimberg | 97 | 1531 | 45944 |
Keith E. Gubbins | 85 | 466 | 35909 |
Peter K. Liaw | 84 | 1068 | 37916 |
Katsushi Ikeuchi | 78 | 636 | 20622 |
Mark R. Cutkosky | 77 | 393 | 20600 |
M. S. Skolnick | 73 | 728 | 22112 |
David D. Woods | 72 | 318 | 20825 |
Martin A. Uman | 67 | 338 | 16882 |
Michael Keidar | 67 | 566 | 14944 |
Terry C. Hazen | 66 | 354 | 17330 |
H. Harry Asada | 64 | 633 | 17358 |
Michael T. Meyer | 59 | 225 | 26947 |